An experimental study on the influence of synchronous grouting during shield tunnel construction on vertical displacement and surrounding earth
pressure in sandy soil
|更新时间:2026-06-25
|
An experimental study on the influence of synchronous grouting during shield tunnel construction on vertical displacement and surrounding earth
pressure in sandy soil
HUANG Da-wei, LU Wen-jian, LUO Wen-jun, et al. An experimental study on the influence of synchronous grouting during shield tunnel construction on vertical displacement and surrounding earth
pressure in sandy soil[J]. 2025, 46(9): 2837-2846.
DOI:
HUANG Da-wei, LU Wen-jian, LUO Wen-jun, et al. An experimental study on the influence of synchronous grouting during shield tunnel construction on vertical displacement and surrounding earth
pressure in sandy soil[J]. 2025, 46(9): 2837-2846.DOI: 10.16285/j.rsm.2024.1319.
An experimental study on the influence of synchronous grouting during shield tunnel construction on vertical displacement and surrounding earth
pressure in sandy soil
To investigate the influence mechanism of synchronous grouting in shield tunnel on vertical displacement and earth pressure of sandy soil stratum
model tests were conducted to study the vertical displacement and earth pressure of the upper stratum during synchronous grouting. The results indicate that with the same filling coefficient of synchronous grouting material
the upper stratum rises and earth pressure increases after injecting small water content slurry
whereas it settles and earth pressure decreases after injecting large water content slurry. Similarly
with consistent water content in the grouting material
reducing the filling coefficient significantly decreases the uplift of the upper stratum and reduces the extrusion pressure on the upper stratum of the tunnel. Vertical earth pressure increases and passive soil arching occur when the upper stratum uplifts
while vertical earth pressure decreases and active soil arching occur when the stratum settles. During on-site synchronous grouting
the filling coefficient should be determined based on the consolidation shrinkage of the slurry and stratum permeability
and grouting parameters should be adjusted according to on-site monitoring results.