Research on the anchor cable combined with the c-shaped tube and the mechanical properties
In order to prevent the anchor cable from shearing and breaking in the surrounding rock of the roadway
and to further improve the shear strength of the anchor cable
we independently developed the anchor cables combined with the c-shaped tube (ACC)
which can improve the shear strength and stability of the surrounding rock. The design is mainly composed of c-shaped tube and anchor cables. We first introduce the ACC support structure in detail. In order to better study the mechanical properties of ACC
the indoor mechanical properties tests of ACC and pure anchor cables have been carried out with different types
different prestresses and different cable diameters
with the help of the self-developed new type of anchor able with c-shaped tube tension-shear testing system. We compare and analyze the test results based on the characteristics of the force-shear displacement plot
the effects of the supporting member type
and the failure mode of the supporting structure. The results show that the anchor cable and its combined structure with c-shaped tube undergo three stages in the shearing process
which includes the free deformation of the bore-wall rock
the compression of the c-shaped steel tube by the bore-wall rock
and the joint deformation of the c-shaped tube wrapped with the anchor cable. The shear fracture of ACC is manifested as tensile fracture and tensile-shear composite fracture. Its peak shear force is negatively correlated with the pretension force. Compared with the pure anchor cable
the axial distance of the shear plastic hinge of ACC is larger. The maximum shear force
the maximum axial force and the overall structural deformation capacity of ACC have been improved by 26.8%
3.5%
and 7%
respectively. The test results show that the use of ACC can effectively improve the overall shear resistance of the joint surface. When the surrounding rock is deformed and damaged
the combined structure of the anchor cable and the c-shaped steel cube can not only increase the shear strength of the entire supporting system
but also increase the tensile strength of the anchor cable at the same time. Therefore
the supporting effect of the anchor cable plus the c-shaped tube can achieve the fact where 1+1>2. The combination of two forms an effective surrounding rock bearing circle around the roadway
and the stability can be guaranteed for the surrounding rock of the roadway.