LIU Wei-ning, JIANG Bo-long, MA Meng, et al. Elementary experimental investigation of the periodic piles
for vibration isolation of design frequency range[J]. 2019, 40(11): 4138-4148.
DOI:
LIU Wei-ning, JIANG Bo-long, MA Meng, et al. Elementary experimental investigation of the periodic piles
for vibration isolation of design frequency range[J]. 2019, 40(11): 4138-4148.DOI: 10.16285/j.rsm.2019.0757.
Elementary experimental investigation of the periodic piles
for vibration isolation of design frequency range
The current research on the periodic piles for vibration isolation based on the method of band gap mainly focused on theoretical and numerical analysis. In this paper
the method of principle experiment was adopted to validate the characteristics of attenuation zone of the periodic piles for vibration isolation. Four experimental cases were designed to consider two types of periodic piles (i.e.
hollow steel piles and periodic hollow steel piles filled with soil) and two types of periodic layout (i.e.
a hexagonal configuration and a square configuration). With the excitation of impulsive loads
the experimental cases with vibration isolation measures were compared to those without vibration isolation measures. Vibration attenuations of the periodic piles in various experimental cases were measured
analyzed and compared with theoretical band gaps. The measured vibration response in various experimental cases was greatly attenuated within the band gaps of theoretical calculations. The levels of attenuation were above 50% and the highest one was up to 98%. Both the attenuation effect and vibration isolation performance were greatly achieved
and thus the effectiveness of theoretical analysis is verified. The horizontal level of vibration attenuation of the periodic piles is better than the vertical. From this trend
with the same conditions
the vibration attenuation level of periodic piles in a hexagonal configuration was better than those in a square configuration. Moreover
soil-filling could effectively increase the width of the initial band gap and the attenuation zone of periodic steel pipe piles arranged in a hexagonal configuration
but reduce the lower bound frequency of the initial band gap and the attenuation zone of periodic steel pipe piles arranged in a square configuration. By analysing the band gap of periodic piles that were approximate to actual engineering dimensions corresponding to the periodic piles in the experimental cases
it is found that there are several band gaps appearing in the frequency range of 0-80 Hz which can be lower than 20 Hz. This study further illustrates that an objective frequency range can be designed to be isolated by periodic piles
and the periodic piles based on band gap theory can have a broad application prospect in the vibration isolation induced by metro train.
Experimental investigations on engineering mechanical properties of sandstone in the deflection fractured zone in dam foundation of a hydropower station
Experimental investigation on strength and deformation properties of clastic sandstone under triaxial compression
Multiple scattering of SH waves by rows of arbitrarily arranged tubular piles
Study of unloading triaxial rheological tests and rules of joint pelitic siltstone
Strength development model for slurry-like mud treated by physicochemical combined method considering preloading stress
Related Author
MEI Song-hua
GU Jin-jian
XU Wei-ya
ZHAO Hai-bin
ZHANG Yu
MEI Song-hua
WANG Wei
ZHAO Hai-bin
Related Institution
Geotechnical Research Institute, Hohai University
College of Pipeline and Civil Engineering, China University of Petroleum
Hunan Provincial Key Laboratory of Hydropower Development Key Technology, Zhongnan Engineering Corporation
Hunan Provincial Key Laboratory of Hydropower Development Key Technology, HydroChina Zhongnan Engineering Corporation
Research Institute of Geotechnical Engineering, Hohai University