ZHENG Li-fu, GAO Yong-tao, ZHOU Yu, et al. Research on optimization of frozen wall thickness of underwater tunnel
based on fluid-solid coupling theory[J]. 2020, 41(3): 1029-1038.
DOI:
ZHENG Li-fu, GAO Yong-tao, ZHOU Yu, et al. Research on optimization of frozen wall thickness of underwater tunnel
based on fluid-solid coupling theory[J]. 2020, 41(3): 1029-1038.DOI: 10.16285/j.rsm.2019.0702.
Research on optimization of frozen wall thickness of underwater tunnel
based on fluid-solid coupling theory
The design of underwater tunnel has special requirements for the thickness of the frozen wall. To improve the frozen wall design of the contact channel in the Maliuzhou waterway section of the Zhuji Intercity Rail Transit Project
based on the fluid-solid coupling theory
the finite difference method is adopted to analyze the stability of the underwater tunnel numerically. By simulating underwater tunnel with different frozen wall thickness
the responses of underwater tunnel stability to the thickness of frozen wall are discussed and the optimizaitons of frozen wall ticknesses are done. The results of simulation show: compared with the non-permeability model
the fluid-solid coupling model has the same distribution of stress on the frozen wall
but the overall values are obvious larger
which means the effect of water cannot be ignored. Due to the existence of water
the frozen wall tends to be “homogeneous” and the stress concentration phenomenon is alleviated
but the distribution range of high shear stress is expanded
which increases the risk of shear damage
and the frozen wall is changed to be under the tension from the pressure
which decreases structural stability. The deformation of the frozen wall is intensified under influence of the fluid-solid coupling and increase with the decreases of the thickness until the thickness of the model reaches 2.0 m or more
where the deformation of the frozen wall is basically stable. The plastic zones of the fluid-solid coupling models mostly exist at the arched areas on both sides
no plastic zone is formed in the models with 3.0 m and 2.5 m thickness
the plastics are formed in the opposite sides of the model with 2.0 m thickness
the plastic zone is almost going through in the models with 1.5 m thickness
the damage zone is formed obviously at frozen wall arch of the model with 1.0 m thickness. The thickness of 2.5 m is selected as the optimized thickness of the frozen wall. This optimized thickness is directly applied to the design of the No.4 communication channel
which is constructed by a freezing method. Through the on-site monitoring test
the validity and the effectiveness of the optimization scheme are verified
which means this optimization scheme has essential promotion and application value for the design of frozen wall thickness in similar projects.