LI Lian-xiang, HUANG Jia-jia, FU Qing-hong, et al. Centrifuge experimental study of mechanical properties of composite foundation with different replacement rates under additional load[J]. 2017, 38(S1): 131-139.
DOI:
LI Lian-xiang, HUANG Jia-jia, FU Qing-hong, et al. Centrifuge experimental study of mechanical properties of composite foundation with different replacement rates under additional load[J]. 2017, 38(S1): 131-139.DOI: 10.16285/j.rsm.2017.S1.015.
Centrifuge experimental study of mechanical properties of composite foundation with different replacement rates under additional load
Replacement rate is one of the key indicators for designers to determine the composite foundation of CFG piles. After determining the pile length according to the distribution of soil layer
the choice of replacement rate is the basis of vertical structure system decision-making according to additional load for target. At present
we have a lack of common knowledge and understanding of the mechanical properties of composite foundation affected by additional load under different replacement rates. Two centrifuge model tests with the same additional load and reinforcement depth and different replacement rates have been carried out to study the change law of the pile axial forces
pile side frictional resistances
pile-soil stress ratio and foundation settlement of the composite foundation during loading process. As the increase of the replacement rate
the test results show that: (1) The axial force of CFG pile is reduced; and the position of the maximum axial force is up along the pile. (2) The positions that the direction of pile side frictional resistance changes or that has the maximum negative frictional resistance in the upper part of the pile are also up along the pile; and the rate of change of the latter is reduced. The maximum positive frictional resistance in the lower part of the pile is obviously reduced. (3) The pile-soil stress ratio is reduced and its reduced rate along the depth direction in deep soil is decreased. (4) The foundation settlement and the ground surface settlement are effectively decreased; and the surface settlement changes linearly with the load; and the composite modulus of CFG composite foundation is improved.
Analysis of pile-soil stress ratio of cast-in-place X-section concrete pile composite foundation under rigid base
Study of calculating method of low strength piles composite foundation settlement
Experimental study and finite element analysis of cushion in CFG pile composite foundation
Test study on influence of cushion on loading behavior of composite foundations
Experimental study on load-bearing characteristics for single PTC pile with cap and composite foundation with PTC (prestressed thin-wall concrete) piles
Related Author
Lü Ya-ru
DING Xuan-ming
LIU Han-long
CUI Yun-liang
GUO Chao
YAN Shu-wang
XIAO Shi-wei
CHEN Ze-lian
Related Institution
Key Laboratory of Ministry of Education for Geomechanics and Embankment Engineering, Hohai University
Geotechnical Research Institute, Hohai University
National Engineering Research Center of Water Resources Efficient Utilization and Engineering Safety, Hohai University
School of Civil Engineering, Tianjin University
The Third Railway Survey & Design Institute Group Corporation