LI Li-hua, SHI An-ning, XIAO Heng-lin, et al. Model test and mechanical properties study of reinforced earth retaining wall[J]. 2018, 39(12): 4360-4368.
DOI:
LI Li-hua, SHI An-ning, XIAO Heng-lin, et al. Model test and mechanical properties study of reinforced earth retaining wall[J]. 2018, 39(12): 4360-4368.DOI: 10.16285/j.rsm.2017.1334.
Model test and mechanical properties study of reinforced earth retaining wall
Model tests in laboratory were conducted to investigate the behaviors of reinforced earth retaining wall of block face under the loading on the top of the retaining wall. In the model test
four conditions were simulated. The results show that
the vertical earth pressure on the upper part of retaining wall increases rapidly and the maximum vertical earth pressure of each layer moves from the lower part of the loading point to the face of wall. When the load at the top of wall exceeds 130 kPa
due to uneven settlement
the wall surface corresponding to fifth layer of reinforcement tends to shrink inward
the maximum horizontal displacement of wall surface is located in 7/10 of the wall height. In the whole loading stage
the overall strain value of the reinforcement does not increase significantly and the actual strain value of the reinforcement is much smaller than the maximum design strain of the reinforcement. Both increasing the number of the reinforced layers in the retaining wall and increasing the length of reinforcement can improve the performance of the retaining walls. However
the effect of increasing the number of the reinforced layers is better than that of increasing the length of reinforcement. The use of waste tire instead of unidirectional geogrid can effectively improve the overall performance of retaining walls
disperse additional stress caused by overloading
reduce the horizontal displacement of the face of wall and the vertical displacement at the top of the wall.