KONG Gang-qiang, WANG Cheng-long, LIU Han-long, et al. Analysis of pile head displacement of energy pile under repeated temperature cycling[J]. 2017, 38(4): 958-964.
KONG Gang-qiang, WANG Cheng-long, LIU Han-long, et al. Analysis of pile head displacement of energy pile under repeated temperature cycling[J]. 2017, 38(4): 958-964.DOI: 10.16285/j.rsm.2017.04.005.
Analysis of pile head displacement of energy pile under repeated temperature cycling
Energy pile is a new technology which supports the upper building load and extracts geothermal energy from its surrounding simultaneously.However
there is only little research available on the thermal-mechanical behavior of the piles subject to heating-cooling cycles and particularly repeated cycles.Model tests are carried out to examine the heat transfer performance and bearing characteristics of energy pile with embedded steel tube under working loading conditions over repeated temperature cycling
and especially the law of pile head displacement.Moreover
the displacement is also observed and analyzed under no load over one cycle of heating and cooling for comparative analysis.The results show that the heating-cooling cycles produce thermal strain in the pile shaft
heating generates compressive stress and cooling induces the tensile stress.Meanwhile
the positive and negative frictions are yielded in different parts of the pile side due to temperature.The upward displacement magnitude of pile top under no working load is 41%greater than that under working load
but the final displacement of pile top is approximately 10%of that under working load after one heating-cooling cycle.The repeated temperature cycling can lead to continuous accumulation of settlement.