ZHANG Yu-wei, XIE Yong-li, WENG Mu-sheng. Centrifugal test on influence of asymmetric foundation excavation to an underlying subway tunnel[J]. 2018, 39(7): 2555-2562.
DOI:
ZHANG Yu-wei, XIE Yong-li, WENG Mu-sheng. Centrifugal test on influence of asymmetric foundation excavation to an underlying subway tunnel[J]. 2018, 39(7): 2555-2562.DOI: 10.16285/j.rsm.2016.2243.
Centrifugal test on influence of asymmetric foundation excavation to an underlying subway tunnel
The unloading-reloading conditions during an asymmetric foundation excavation usually are harmful to the underlying subway tunnel. To verify the disturbance of foundation excavation
the modified centrifugal system was used to simulate different excavation steps
and the load transfer of foundation-soil-tunnel
considering the relative position of tunnel and foundation pit. The results show ground loss due to the excavation
tunnel float and offset induced by asymmetric unload. The disturbance of first excavation step was small
and became stronger as the excavation depth increases; the left tunnel close to foundation center was disturbed more significantly. Longer distance to the foundation and tunnel generates weaker the disturbance by unload-reload. The force of tunnel lining was redistributed because of the foundation load influence after loading. The disturbance of the section lying between piles was obvious. The section lying one-sided pile was small
the disturbance of pile group effect was more obvious.