The allowable values of the factor of safety in gravity retaining wall design in various Chinese codes are discussed
and it is concluded that these allowable values are generally smaller than those adopted in many foreign country codes. Theoretically
the factor of safety is defined as the resistance divided by earth pressure
where the earth pressure is the one determined by using the non-corrected strength parameters instead of the reduced strength
and thus the resulting allowable factor of safety should be larger than that adopted in the design of the equivalent retaining structure. To resolve this problem
limit state design with partial factors is applied to retaining wall design problem. For Class 1 structures
its target reliability index is 3.7. Assuming the coefficients of variability of 0.2 and 0.1 for cohesion and friction
respectively
the calibrated partial factors are 1.301
1.209 and 1.170. The calibrated partial factors are validated by the ‘ratio of safety margin’ theory proposed by the authors’ research team. The discussion of this paper provides some useful guidelines for code makers.