Fault inrush current generation mechanism of inverter-side converter transformer and its influence on differential protection
Since fault inrush current of converter transformer may be initiated by the grounding fault at valve side of inverter side of UHVDC system,the difference of valve bridge on-off condition with fault at converter bridge of different voltage levels and at different times is discussed,the fault current characteristics at valve side after commutation failure are analyzed,and the generation mechanism and characteristics of fault inrush current at inverter side are described. On this basis,the operation characteristics of conver-ter transformer differential protection considering the influence of fault inrush current are analyzed. Research results show that the fault inrush current may cause mal-block of differential protection at the transition of out-zone fault to in-zone fault of converter transformer,aiming at this problem,a novel solution scheme to prevent mal-block of differential protection is proposed according to the characteristics of polarity reversal of valve side DC component when fault occurs. Simulative results on PSCAD/EMTDC verify the correctness of theoretical analysis.
LUO Hanwu , LE Jian , MAO Tao , et al . Analysis of operation characteristics of Zhalute-Qingzhou ±800 kV UHVDC system [J]. Electric Power Automation Equipment , 2019 , 39 ( 1 ): 53 - 59 .
WENG Hanli , LIN Xiangning . Analysis and countermeasure of abnormal operation behaviors of the differential protection of converter transformer [J]. Proceedings of the CSEE , 2009 , 29 ( 31 ): 87 - 94 .
ZHENG Tao , GUO Xingchao , HU Xin , et al . Research on the fault-induced inrush current of the converter transformer and its impacts [C]∥ 2018 2nd IEEE Conference on Energy Internet and Energy System Integration(EI2) . Beijing,China : [s.n.] , 2018 : 1 - 6 .
HAN Kunlun . Research on dynamic characteristic and protection setting of HVDC converter and line protection [D]. Guangzhou : South China University of Technology , 2013 .
HAN Kunlun , CAI Zexiang , LI Jiaman , et al . Analysis of fault on the AC side of converter and action of converter protection considering DC control [J]. High Voltage Engineering , 2014 , 40 ( 8 ): 2531 - 2540 .
LI Xiaohua , LIU Yang , CAI Zexiang . Analysis of grounding fault at HVDC converter transformer valve side [J]. Transactions of China Electrotecnical Society , 2012 , 27 ( 6 ): 38 - 45 .
LIU Yang , LI Xiaohua , CAI Zexiang . Location of HVDC converter grounding fault [J]. Automation of Electric Power Systems , 2010 , 34 ( 8 ): 86 - 91 .
LIU Yang . Research on feature analysis and protection improvement of HVDC converter grounding fault [D]. Guangzhou : South China University of Technology , 2011 .
ZHU Taoxi , WU Cheng , WANG Chao . Influence of AC system fault on HVDC system and improvement suggestions [J]. Automation of Electric Power Systems , 2009 , 33 ( 1 ): 93 - 98 .
SHEN Hongming , SONG Xuankun , HUANG Shaofeng , et al . Effect of commutation failure on transfer characteristics of CT and differential protection of converter transformer [J]. Electric Power Automation Equipment , 2018 , 38 ( 4 ): 218 - 223 .
LI Wei , XIAO Xiangning , GUO Qi . Micro-analysis of valve com-mutation process during DC commutation failure [J]. Electric Power Automation Equipment , 2017 , 37 ( 3 ): 115 - 119,183 .
ZHENG Tao , HU Xin . Fault inrush current mechanism of UHV converter transformer and its impacts on differential protection [J]. Electric Power Automation Equipment , 2019 , 39 ( 5 ): 109 - 115 .
YANG Peng , WU Yani , MA Shicong , et al . Analysis of commutation failure of healthy pole during restart of faulty line for ±1 100 kV UHVDC project [J]. Electric Power Automation Equipment , 2016 , 36 ( 4 ): 14 - 18 .