Boiler air preheater in power plant is a kind of equipment which uses the heat of flue gas in the boiler tail flue to heat the boiler air
so as to reduce the loss of exhaust gas
increase the temperature of inlet air and improve the efficiency of boiler
if the air preheater of the boiler is blocked
it will seriously affect the full load operation of the boiler
so it is very important to take effective preventive measures to avoid the air preheater blocking. Through the discussion on the cause of the blockage of the boiler air preheater in the power plant
the main causes of the blockage were found to be low steam injection pressure
low fan inlet temperature
high exhaust gas temperature
low metal surface temperature of the preheater and coal quality
after taking effective measures such as strengthening the management of raw coal
preventing the abnormal air preheater and setting the air preheater to blow ash correctly
the blockage of the air preheater was effectively controlled.