刘敏. Energy Saving of Economizer in 330MW Circulating Fluidized Bed Boiler Reform[J]. 2019, (3): 102-104. DOI: 10.16056/j.1005-7676.2019.03.029.
Energy Saving of Economizer in 330MW Circulating Fluidized Bed Boiler Reform
摘要
FY电厂330 MW循环流化床锅炉省煤器运行10年来
多次发生爆管、吹损停炉事件
中高温段磨损尤为严重
同时由于爆管问题
现已有25排管子实行了堵管措施
造成现行锅炉排烟温度偏高
已经严重影响到锅炉的安全性和经济性。为解决磨损严重造成的排烟温度偏高问题
技术人员经过调研分析
提出更换中高温段
保留低温段的改造方案
在实施中得到了很好的效果
不但设备运行良好还带来了不菲的经济效益。
Abstract
In the past 10 years
the economizer of 330 MW CFB boiler in FY power plant has been running for many times
such as tube burst
blown-out and stoppage. The abrasion of medium and high temperature section is particularly serious. At the same time
due to tube burst
25 tubes have been blocked up
resulting in high exhaust gas temperature of the current boiler
which has seriously affected the safety and economy of the boiler. In order to solve the problem of high exhaust gas temperature caused by severe wear and tear
technicians
through investigation and analysis
put forward the transformation scheme of replacing middle and high temperature section and retaining low temperature section