上海电力修造总厂生产的DGT600-250汽动给水泵返厂检修后
装复试运过程中出现推力瓦温持续升高
机组负荷超过160 MW时推力瓦温度超过报警1值
并且随着负荷升高推力瓦温仍持续升高
通过分析润滑油压、油温、流量、油路等方面的问题
查找出推力瓦温高的原因
提出有效处理措施解决了推力瓦温高的现场难题。
After the DGT600-250 steam feed pump produced by Shanghai Electric Power Repair and Repair Plant was returned to the factory for repair
the thrust tile temperature continued to rise during the trial and test. When the unit load exceeded 160 MW
the thrust tile temperature exceeded the alarm 1 value
and As the load increases
the thrust tile temperature continues to rise. By analyzing the problems of lubricating oil pressure
oil temperature
flow rate
oil path
etc.
the cause of thrust tile temperature high is found out
and effective treatment measures are proposed to solve the thrust tile temperature is high on-site puzzles.