钟振坤, 尹中诚, 任绍军. Cause Analysis and Treatment of Gas Accumulation in 600 MW Steam Turbine Closed Water System[J]. 2018, (4): 78-81. DOI: 10.16056/j.1005-7676.2018.04.021.
Cause Analysis and Treatment of Gas Accumulation in 600 MW Steam Turbine Closed Water System
摘要
针对某600 MW电厂汽轮机组闭式冷却水在正常运行时由于积气多母管压力突降
分析了现场检查、处理的结果
对比故障前后的数据
找出发生故障的原因为疏水器故障、省煤器发送罐圆顶阀故障和凝汽器补水阀内漏。通过更换缺陷设备
制定相应的防范措施
解决了闭式水积气的问题
保障了机组的安全运行。
Abstract
Due to the pressure drop of the manifold when the closed cooling water of a 600 MW power plant steam turbine during normal operation. This paper analyze the results of on-site inspections and compare data before and after failure
then it find out the cause of the failure is the steam trap failure
the economizer sending tank dome valve fault and the condenser water filling valve inner leakage. By replacing the defective equipment and formulating corresponding preventive measures
the problem of closed-type water accumulation gas is solved