吕新乐, 傅斌, 罗江勇, et al. Analysis and Solution of Vibration and Leakage of Superheater Water Reducing Valve[J]. 2018, (3): 75-78. DOI: 10.16056/j.1005-7676.2018.03.018.
Analysis and Solution of Vibration and Leakage of Superheater Water Reducing Valve
There are 2 problems in the temperature control valve of our plant: 1) the valve has obvious vibration in certain opening interval; 2) the valve stem leaks easily. High temperature and high pressure valve leakage will cause greater damage to nearby equipment and personnel. Through calculation and analysis
this paper finds out the cause of the problem: the valve type selection is unreasonable. After improvement
the above problem is solved and the safety of the equipment is improved.