沈训欢, 谢俊宏, 傅斌, et al. Influence and Analysis of DC Bias on Excitation Characteristic and Reactive Power of Main Transformer in Power Plant[J]. 2017, (2): 70-74.
沈训欢, 谢俊宏, 傅斌, et al. Influence and Analysis of DC Bias on Excitation Characteristic and Reactive Power of Main Transformer in Power Plant[J]. 2017, (2): 70-74. DOI: 10.16056/j.1005-7676.2017.02.017.
Influence and Analysis of DC Bias on Excitation Characteristic and Reactive Power of Main Transformer in Power Plant
摘要
利用PSCAD软件模块
采用直流输电系统和电厂主变的真实结构参数建模
将电阻等效分流法与模型仿真结合在一起
从系统的层面上
有效地分析了直流偏磁对电厂主变压器励磁特性和无功功率的影响
并直观的表述了变压器中性点处直流分量增大时励磁电流和无功功率的变化规律。
Abstract
The model was builted based on the structure and parameters of high voltage direct current transmission system and main transformer in power plant. The influence of DC bias on excitation characteristic and reactive power of main transformer in power plant was analyzed effectively in a whole system by using the equivalent method of shunt resistance to simulate. And the change law of excitation current and reactive power while the DC component of main transformer neutral point increasing was described visually in this paper.