A test has been conducted about the vibration of mechanical press. According to the test data
the performance differences and advantages and disadvantages between the spring damper and rubber isolator are analyzed
confirms the fluid damping performance
and analyzes the law of mechanical press structure vibration under different conditions
which including the presence in various forms of overall vibration
relationship between press structure vibration magnitude and working conditions
source of structure vibration damping
and provide a reference for press design and vibration isolators selection. The base vibration of spring damping vibration isolator is 1/5 of which of rubber vibration isolator
Body structure vibratio
n level and the graph of the relationship between load under different conditions could be used as reference when designers selecting electrical components. During clutch braking process
beam body vibration acceleration amplitude 3
8
g;significant energy coupling phenomenon between low frequency of multi link press pass system and the vibration of the whole press. The result is that spring vibration isolator performs better than rubber vibration isolator in press damping
multi link press vibrates less than eccentric press.