1. 江西联动锅炉设备有限公司
2. 山东滕州盛源热电有限公司
Published:2015
移动端阅览
[1]陈剑,单涛.1台75t/h循环流化床锅炉的改造设计[J].能源研究与管理,2015(04):114-116.
陈剑, 单涛. Transforming Design of a 75t/h Circulating Fluidized-bed Boiler[J]. 2015, (4): 114-116.
[1]陈剑,单涛.1台75t/h循环流化床锅炉的改造设计[J].能源研究与管理,2015(04):114-116. DOI: 10.16056/j.1005-7676.2015.04.033.
陈剑, 单涛. Transforming Design of a 75t/h Circulating Fluidized-bed Boiler[J]. 2015, (4): 114-116. DOI: 10.16056/j.1005-7676.2015.04.033.
对1台75 t/h循环流化床锅炉的埋管、低温过热器、分离器和三次风系统等进行改造
解决了该锅炉出力不足、烟气氮氧化物排放和受热面磨损等问题
达到节能环保要求
提高了锅炉的热效率
给公司取得了不错经济效益。
The boiler tube
low-temperature super-heater
separator and tertiary air system of a 75 t/h CFB boiler were transformed
it solved the problem of insufficient output
NOX emission of flue and erosion of heating surface etc..Meanwhile
it can meet the requirement of energy conservation and environmental protection
improved thermal efficiency of boiler and achieved remarkable economic benefits for the factory.