LIU Huijuan, YI Yuanyuan, ZHANG Zhenyang, et al. Influence of structural parameters on performance of annular linear induction electromagnetic pump[J]. Electric Machines and Control, 2024, 28(4): 92-101.
DOI:
LIU Huijuan, YI Yuanyuan, ZHANG Zhenyang, et al. Influence of structural parameters on performance of annular linear induction electromagnetic pump[J]. Electric Machines and Control, 2024, 28(4): 92-101. DOI: 10.15938/j.emc.2024.04.010.
Influence of structural parameters on performance of annular linear induction electromagnetic pump
Annular linear induction electromagnetic pump(ALIP)is a key drive device for pumping coolant in liquid metal reactors. In the design and analysis of the electromagnetic pump,the structural parameters are important factors affecting the output performance of the electromagnetic pump. In order to further study the influence of the structural design parameters of the annular linear induction electromagnetic pump on its output performance. Firstly,the finite element analysis software was used to establish a simulation model of the annular linear induction electromagnetic pump by considering the effect of the end effect and the influence of the annular conductive pipeline,and then,based on this model,the influence of the different gear ratios,the height of the flow channel and the thickness of the pipeline wall on the electromagnetic pump's magnetism density distribution,the electromagnetic density distribution and the output electromagnetic force was analyzed by calculation. Finally,the output characteristics and efficiency of the toroidal linear induction electromagnetic pump with different structural parameters were further compared and analyzed,and the results provide a reference basis for the optimization of the structural parameters of the toroidal linear induction electromagnetic pump.
关键词
Keywords
references
杨孟嘉,任俊生,周志伟.第4代核能系统研发介绍[J].国际电力, 2004, 8(5): 30.
YANG Mengjia, REN Junsheng, ZHOU Zhiwei. Introduction of R&D on generation IV nuclear energy system[J].International Electric Power for China, 2004, 8(5): 30.
YANG Zhida, ZHAO Jianing, HAN Weishi. Modeling and performance research on sodium cooled fast reactor superconductive sodium pump[J]. Atomic Energy Science and Technology,2014, 48(3): 480.
KIM H R, YONG B L. Adesign and characteristic experiment of the small annular linear induction electromagnetic pump[J]. Annals of Nuclear Energy, 2011, 38(5):1046.
KWAK J, KIM H R. Design and preliminary test of an annular linear induction electromagnetic pump for a sodium-cooled fast reactor thermal hydraulic experiment[J]. Journal of Nuclear Science and Technology, 2017, 54(12): 1292.
KIM H R. The design of a small annular linear induction EM pump for the transportation of liquid sodium in the SFR[C]//2013 21st International Conference on Nuclear Engineering, July 29-August 2, 2013, Chengdu, China. 2013: V002T05A043.
KWAK J, KIM H R. Design optimization analysis of a large electromagnetic pump for sodium coolant transportation in PGSFR[J]. Annals of Nuclear Energy, 2018, 121:62.
KIM H R, KWAK J S. MHDdesign analysis of an annular linear induction electromagnetic pump for SFR thermal hydraulic experimental loop[J]. Annals of Nuclear Energy,2016,92:127.
NASHINE B K, RAO B. Design, in-sodium testing and performance evaluation of annular linear induction pump for a sodium cooled fast reactor[J]. Annals of Nuclear Energy,2014,73:527.
BAKER R S, TESSIER M J. Handbook of Electromagnetic Pump Technology[M]. New York: Elsevier Science Publishing, 1987.
BI Keming, CHEN Shuo, CHAI Baohua,et al. Design and characteristic experiment research on small NaK thermal vacuum electromagnetic pump[J]. Atomic Energy Science and Technology, 2020, 54(3): 512.
ZHANG Z, LIU H, SONG T, et al. One dimensional analytical model considering end effects for analysis of electromagnetic pressure characteristics of annular linear induction electromagnetic pump[J]. Annals of Nuclear Energy, 2022, 165: 108766.
WANG L, HOU Y, SHI L, et al. Experimental study and optimized design on electromagnetic pump for liquid sodium[J]. Annals of Nuclear Energy, 2019, 124: 426.
KWAK J, KIM H R. Development of innovative reactor-integrated coolant system design concept for a small modular lead fast reactor[J]. International Journal of Energy Research, 2018, 42 (13): 4197.
ROMAN R C. Study of the electromagnetic pumping systems of molten metals and molten salts[D]. Grenoble:University Grenoble, 2014.
LI Huiwen, ZHAO Ruijie, SHI Weidong, et al. Numerical simulation and flow analysis of ALIP pumps with different winding arrangements[J]. Journal of Engineering Thermophysics, 2019, 40(1): 98.
ZHAO Ruijie, MIAO Heng, ZHANG Desheng, et al. Three-dimensional transient characteristics and unstable flow of annular linear induction pump[J]. Journal of Drainage and Irrigation Machinery Engineering, 2019, 37(10): 841.
LIU Huijuan, WANG Yu, ZHANG Qian, et al. Optimization of thrust ripple of long primary double sided linear induction motor injected with harmonic current[J]. Electric Machines and Control, 2023, 27(2):49.
ZHANG Mingyuan, SHI Liming, GUO Keyu, et al. Modeling and analysis of segmented long primary double-sided linear induction motor[J]. Transactions of China Electrotechnical Society, 2021, 36(11): 2344.
ZHANG Zhenyang, LIU Huijuan, SONG Tengfei, et al. Optimized model for a linear induction electromagnetic pump based on an end magnetic field function[J]. Journal of Harbin Engineering University, 2022, 43(5): 722.
SHARMA P, NASHINE B K, MANI A. Performance prediction of annular linear induction pump under constant slip frequency operation[J]. Annals of Nuclear Energy, 2020, 147:107677.
ZHANG Z, LIU H, SONG T, et al. The improved equivalent circuit models considering end effects of annular linear induction electromagnetic pump for space nuclear power supply[J]. IEEE Access, 2021, 9: 121493-1.