This paper firstly constructs a physical model of thermal power generation units
and compares the calculated data of the model with the design data of THA
75% THA
and 50% THA operating condition of 300MW units to verify the accuracy of the model. Then
the ternary molten salt is used as the heat storage molten salt. After comparing multiple combined conditions of heat storage and release
the optimal working condition of the heat storage process is to extract the main steam and heating the condensate
and the optimal working condition of the heat release process is to directly produce steam by molten salt. Finally
taking the subcritical 300 MW reheating heating unit as an example
the scheme design and technical and economic evaluation of the molten salt heat storage system are carried out. The results showed that according to the peak shaving auxiliary service rules of Fujian Province
with an average load rate of 50% and an average peak shaving compensation price of 0.2 yuan/kWh
the total investment of the molten salt heat storage system is about 38.7 million yuan
and the static investment recovery period is about 21.2 years.