and construction,EPC)度电成本,且最低的EPC度电成本对应的交流与直流装机比值在1.34附近,对于该地区光伏电站的招投标有一定借鉴意义。
Abstract
Governments around the world are prevalent to seize time to formulate and implement action plans for the peaking and neutralization of carbon dioxide emissions.Solar photovoltaic power generation will be bound to gradually become one of the mainstream directions to replace traditional energy power generation.In this paper
the photovoltaic power stations in the Middle East
where is rich in solar resources
are taken as the research object.Through the research method of simulation
the corresponding relationship between levelized cost of electricity (LCOE) and power station capacity ratio and photovoltaic module type is simulated and analyzed respectively.It is found that based on the current labor
material and machine prices of the area
for the centralized utility solar photovoltaic power plants in the Middle East
the N-type photovoltaic module is more conducive to reducing the EPC-LCOE than the P-type module
and the potential DC/AC ratio corresponding to the lowest EPC-LCOE is around 1.34
which can be used as a reference for the bidding of photovoltaic power plants in this region.