Low-temperature plasma is an emerging disinfection technology that generates multiple reactive species at the gas-liquid interface
forming plasma-activated water. Atomizing this water into a mist enhances the coverage and penetration of reactive species
offering potential for highly efficient sterilization and disinfection. We established a diagnostic platform for microbubble-assisted liquid-phase discharge plasma characteristics
and investigated the electrical and optical properties alongside physicochemical parameters (pH
temperature
NOx− concentration) of such plasmas. We further examined the bactericidal efficacy
biosafety
and metal corrosion potential of plasma-activated water and mist(PAWM). The results show that microbubble-assisted liquid-phase nanosecond pulse discharge enables the stable production of plasma-activated water
with a significant decrease in pH during the activation process
NOx− concentrations accumulate continuously
and NO3− remains more stable. The inactivation efficacy of plasma-activated water mist increases with higher disinfection doses
achieving the killing rates of 99.8% for Staphylococcus aureus and 99.99% for H1N1 at the maximum dose. This inactivation is achieved by disrupting cell membrane integrity
leading to the leakage of intracellular substances. In terms of safety
stainless steel exhibits corrosion resistance
whereas carbon steel shows more pronounced corrosion. Overall
evaluations of cellular
skin
and ocular irritation
along with acute inhalation toxicity
indicate favourable biological safety. This study provides a reference for the application and safety assessment of plasma-activated water and mist sterilization and disinfection.