On the base of 300 MW split-flow recompression and single reheat supercritical CO
2
(S-CO
2
) Brayton cycle
the layout of boiler heating surface optimized. In order to solve the problems of large pressure drop of working fluid and high temperature of furnace tube wall
the furnace structure of S-CO
2
boiler was optimized. In the optimization scheme
furnace of S-CO
2
boiler adopts the single furnace double-tangential circle and the vertical tube structure. The system performance analysis model was built
and both the working fluid pressure drop of furnace side and the temperature of tube wall were calculated and compared with those of the original scheme. The results show that under the design load
the pressure drops of both the superheated cooling wall and the reheated cooling wall in
the optimization scheme are obviously reduced. After optimization
due to the decrease of working fluid pressure loss
the power generation efficiency increases and the standard coal consumption of power generation decreases. Under the design load
the system standard coal consumption of power generation is reduced by 2.8 g/(kW×h). Along the furnace height direction
the maximum temperature of the tube outer wall in the optimization scheme is obviously lower than that of the original scheme
which shows that the optimization scheme has a wider safety margin
so as to ensure the safe operation of the unit.
关键词
Keywords
references
樊泉桂, 主编.锅炉原理[M].中国电力出版社,2008.
杨世铭著.传热学基础[M].高等教育出版社,1991.
Jing Zhou,Chenhao Zhang,Sheng Su,Yi Wang,Song Hu,Liang Liu,Peng Ling,Wenqi Zhong,Jun Xiang.Exergy analysis of a 1000 MW single reheat supercritical CO 2 Brayton cycle coal-fired power plant[J].Energy Conversion and Management,2018.
Enhui Sun,Jinliang Xu,Mingjia Li,Guanglin Liu,Bingguo Zhu.Connected-top-bottom-cycle to cascade utilize flue gas heat for supercritical carbon dioxide coal fired power plant[J].Energy Conversion and Management,2018.
Beijing Key Laboratory of Multiphase Flow and Heat Transfer for Low Grade Energy Utilization, North China Electric Power University, Beijing, 102206, PR China,Beijing Key Laboratory of Multiphase Flow and Heat Transfer for Low Grade Energy Utilization, North China Electric Power University, Beijing, 102206, PR China,Key Laboratory of Thermo-Fluid Science and Engineering of Ministry of Education, School of Energy & Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China,Beijing Key Laboratory of Multiphase Flow and Heat Transfer for Low Grade Energy Utilization, North China Electric Power University, Beijing, 102206, PR China,Beijing Key Laboratory of Multiphase Flow and Heat Transfer for Low Grade Energy Utilization, North China Electric Power University, Beijing, 102206, PR China.Key issues and solution strategies for supercritical carbon dioxide coal fired power plant[J].Energy,2018.
Wengang Bai,Yifan Zhang,Yu Yang,Hongzhi Li,Mingyu Yao.300 MW boiler design study for coal-fired supercritical CO 2 Brayton cycle[J].Applied Thermal Engineering,2018.
Plant System Engineering Division, Institute for Advanced Engineering (IAE), Goan-ro, 51 beon-gil, Baegam-myeon, Cheoin-gu, Yongin-si, Yong-In, Gyeonggi-do 17180, South Korea,Plant System Engineering Division, Institute for Advanced Engineering (IAE), Goan-ro, 51 beon-gil, Baegam-myeon, Cheoin-gu, Yongin-si, Yong-In, Gyeonggi-do 17180, South Korea,Plant System Engineering Division, Institute for Advanced Engineering (IAE), Goan-ro, 51 beon-gil, Baegam-myeon, Cheoin-gu, Yongin-si, Yong-In, Gyeonggi-do 17180, South Korea,Plant System Engineering Division, Institute for Advanced Engineering (IAE), Goan-ro, 51 beon-gil, Baegam-myeon, Cheoin-gu, Yongin-si, Yong-In, Gyeonggi-do 17180, South Korea,Plant System Engineering Division, Institute for Advanced Engineering (IAE), Goan-ro, 51 beon-gil, Baegam-myeon, Cheoin-gu, Yongin-si, Yong-In, Gyeonggi-do 17180, South Korea.Thermodynamic and economic investigation of coal-fired power plant combined with various supercritical CO 2 Brayton power cycle[J].Applied Thermal Engineering,2018.
Dia Milani,Minh Tri Luu,Robbie McNaughton,Ali Abbas.Optimizing an advanced hybrid of solar-assisted supercritical CO2 Brayton cycle: A vital transition for low-carbon power generation industry[J].Energy Conversion and Management,2017.
Mounir Mecheri,Yann Le Moullec.Supercritical CO 2 Brayton cycles for coal-fired power plants[J].Energy,2016.
Yann Le Moullec.Conceptual study of a high efficiency coal-fired power plant with CO 2 capture using a supercritical CO 2 Brayton cycle[J].Energy,2013.