Evaporation Characteristics of Atomized Droplets Sprayed in Flue Gas Flow
Spraying flue gas desulfurization (FGD) wastewater into flue duct is an economical and feasible technology to achieve zero discharge in power plant. To deal with the scale and corrosion on flue walls that exist in the practical application of this technology
the physical and mathematical models are established based on a 300 MW power plant. The Eulerian-Lagrangian approach is used to describe the thermo-fluid behavior of FGD wastewater in flue gas
by which the turbulent flow heat transfer of flue gas is described by the Eulerian framework and the evaporation of water droplets is described using the Lagrangian framework. By numerical simulation the flow evaporation characteristics and influencing factors of FGD wastewater droplets sprayed in flue gas were studied. The diffusion range and trajectories of atomized droplets under different operating conditions were obtained. The following results were gained:higher flue gas temperature and smaller diameter of the atomized droplets contribute to shorter time and distance for complete evaporation. Besides
the arrangement of small-flow-multi nozzles can improve the evaporation of atomized droplets. The spray direction must ensure that the relative movement between atomized droplets and flue gas is enhanced
while the droplets can fully diffuse and contact with the flue gas within a specified distance and time
achieving maximum evaporation of the atomized droplets. However
the initial velocity of atomized droplets
the spray full cone angle of nozzles
and the velocity of flue gas have little influence on atomized droplets evaporation. These research results can provide process design and performance regulation of the FGD wastewater evaporation in flue duct of thermal power plants.
Deng J J, Pan L M, Chen D Q, et al.Numerical simulation and field test study of desulfurization wastewater evaporation treatment through flue gas[J]. Water Science&Technology A Journal of the International Association on Water Pollution Research, 2014, 70(7):1285-1291.
Ma S, Chai J, Chen G, et al.Research on desulfurization wastewater evaporation:Present and future perspectives[J]. Renewable&Sustainable Energy Reviews, 2016(58):1143-1151.
Kim H, Sung N.The effect of ambient pressure on the evaporation of a single droplet and a spray[J]. Combustion&Flame, 2003, 135(3):261-270.
Nasser Ashgriz. Handbook of atomization and sprays[M]. New York: Springer-Verlag New York inc., 2011: 869-879.
Padoin N, Dal'Toé A T O, Rangel L P, et al.Heat and mass transfer modeling for multicomponent multiphase flow with CFD[J]. International Journal of Heat&Mass Transfer, 2014, 73(4):239-249.
Alkhedhair A, Jahn I, Gurgenci H, et al.Numerical simulation of water spray in natural draft dry cooling towers with a new nozzle representation approach[J]. Applied Thermal Engineering, 2016, 98:924-935.
Alkhedhair A, Gurgenci H, Jahn I, et al.Numerical simulation of water spray for pre-cooling of inlet air in natural draft dry cooling towers[J]. Applied Thermal Engineering, 2013, 61(2):416-424.