Pengzhi XU, Pengyuan LIU, Jiajia GAO, et al. Analysis and Elimination of the Cause of Furnace Slagging in a Supercritical Slit Type Burner W-Flame Boiler[J]. Power Generation Technology, 2018, 39(2): 146-152.
DOI:
Pengzhi XU, Pengyuan LIU, Jiajia GAO, et al. Analysis and Elimination of the Cause of Furnace Slagging in a Supercritical Slit Type Burner W-Flame Boiler[J]. Power Generation Technology, 2018, 39(2): 146-152. DOI: 10.12096/j.2096-4528.pgt.2018.023.
Analysis and Elimination of the Cause of Furnace Slagging in a Supercritical Slit Type Burner W-Flame Boiler
In order to study the slagging reason of a 600 MW supercritical W-flame boiler
a test study is carried out. The content includes the slagging position detection
gas composition measurement
the temperature distribution measurement and numerical simulation calculation. The results show that the upper part of the down furnace area's temperature is above 1 300 degrees and higher than the softening temperature of the coal; oxygen concentration is low
the concentration of CO is above 10 000 μL/L
showing a strong reducing atmosphere
where is obvious tendency of slagging; the special flow field are also analyzed. According to the analysis of the test results
targeted measures are taken to solve the slagging problem of this W-flame boiler furnace
and the boiler's reliability has been improved obviously.
Ren Feng, Li Zhengqi, Liu Guangkui, et al.Combustion and NOx emissions characteristics of a down-fired 660-MWe utility boiler retro-fitted with air-surrounding-fuel concept[J].Energy, 2011, 36(1):70-77.
State Key Laboratory of Control ang Simulation of Power Systems and Generation Equipment (Department of Energy and Power Engineering,Tsinghua University), Haidian District
School of Energy, Power and Mechanical Engineering, North China Electric Power University, Changping District