Analysis on Energy Saving Effect of Low-Pressure Economizer in Boiler Under Multi-variable Factors
The energy saving effect of low-pressure(LP) economizer of a 220 MW unit was tested under multivariate factors. Using equivalent enthalpy method
the energy saving effect of LP economizer at different operation modes and different operating parameters has been calculated. For 200MW grade units
when it is necessary to have higher water flow rate and inlet temperature of LP economizer
the condensate water from NO.6 LP heater outlet should be used priority. Under the condition of 220 MW
the optimal flow rate into LP economizer is about 250 t/h
increasing thermal efficiency of the unit by 0.645%. If the inlet water is from the outlet of NO.7 and NO.8 LP heater
the LP economizer inlet temperature is lower
the outlet of the LP economizer should return to the outlet of NO.6 LP heater. And water temperature at LP economizer outlet should be slightly higher than that of NO.6 LP heater outlet. Otherwise
the energy efficiency will decrease compared with the best condition. Under the condition of 220MW
370 t/h condensate water is extracted from outlet of NO.8 and NO.7 LP heater
entering main condensate water pipe at outlet of NO.6 LP heater after heated. The heating efficiency of the unit increases 2.003%. For different LP economizer operation mode
there are an optimal water returning location and optimal inlet flow.
Analysis of Influence of Flue Gas Recirculation on Thermodynamic Performance and Economic Efficiency of 125 MW Supercritical CO2 Coal-Fired Power Generation Unit
Optimization Method of Flow Field for Alleviating Clogging of Mist Eliminator in Desulfurization Tower
Application Status and Existing Problem Analysis of the Natural Draft Cooling Towers With Flue Gas Injection Technology in Thermal Power Plants
Experiment on Multi-Component Synchronous Test of Reducing Atmosphere Adjacent to Water Wall of High Temperature Corrosion Boiler
Study of Probe Distribution for Furnace Acoustic Tomographic Temperature Measurement
Related Author
XIANG Jun
CHEN Jing
LIU Hui
ZHU Meng
WANG Can
CHEN Lei
ZHOU Jing
HU Song
Related Institution
State Key Laboratory of Coal Combustion (Huazhong University of Science and Technology)
CHN Energy Group New Energy Technology Research Institute Co., Ltd., Chaoyang District
GD Power Development Co., Ltd., Chaoyang District
School of Energy and Power Engineering, Changsha University of Science and Technology
Department of Environmental Science and Engineering, North China Electric Power University