Yajuan LENG, Rui HU, Lin CUI, et al. Study on Energy Efficiency Characteristics of Wet Flue Gas Desulfurization Tower[J]. Power Generation Technology, 2020, 41(5): 543-551.
DOI:
Yajuan LENG, Rui HU, Lin CUI, et al. Study on Energy Efficiency Characteristics of Wet Flue Gas Desulfurization Tower[J]. Power Generation Technology, 2020, 41(5): 543-551. DOI: 10.12096/j.2096-4528.pgt.20076.
Study on Energy Efficiency Characteristics of Wet Flue Gas Desulfurization Tower
Aiming at the lack of energy efficiency law of wet flue gas desulfurization
this paper takes the wet flue gas desulfurization tower of a 150 MW unit which has been in ultra low emission standard as the research object. An energy efficiency index of desulfurization
namely desulfurization energy efficiency value
was constructed based on the main energy consumption and desulfurization efficiency of the desulfurization equipment. The effects of liquid/gas ratio
inlet flue gas volume
flue gas velocity
inlet SO
2
concentration
flue gas temperature and different spray layer combinations on the desulfurization energy efficiency characteristics were studied by combining numerical simulation and theoretical analysis. The results show that the desulfurization energy efficiency value ranges from 0.22 kg/(kW·h) to 0.96 kg/(kW·h)
and changes in direct proportion with the inlet SO
2
concentration
changes in inverse proportion with the number of spray layer combinations
liquid-gas ratio and inlet flue gas temperature
with the inlet flue gas volume and the flue gas flow rate in the tower rises first and then decreases. This study provides a reference for desulfurization technology evaluation a
nd energy-saving operation of desulfurization system.
Ministry of Ecology and Environment of the People's Republic of China.Notice on the issuance of the "Comprehensive implementation of the work plan for ultra-low emissions and energy saving retrofits of coal-fired power plants"[EB/OL ] .(2015-12-11)[2020-08-01 ] . http://www.zhb.gov.cn/ http://www.zhb.gov.cn/ .
Li W D, Gao H H, Cai W F.Scaling analysis and preventive measures of limestone-gypsum wet flue gas desulfurization[J].Power Generation Technology, 2019, 40(1):51-55.
Zhang J H, Feng Y S.Discussion on environmental protection supervision on FGD system operation incoal-fired power plant[J].Huadian Technology, 2018, 40(12):63-65.
Wang X, Meng D D, Yang T, et al.Reaction characteristic of soda residue used in WFGD in coal-fired power plants[J]. Guangdong Electric Power, 2018, 31(5):21-27.
Long H, Zhong M H.Analysis of main factors affecting auxiliary power consumption rate of wet flue gas desulphurisation for 600 MW unit[J].Electric Power, 2006, 39(2):74-77.
王建峰.工业锅炉湿法脱硫喷淋塔流场优化与传质数值模拟[D].哈尔滨: 哈尔滨工业大学, 2011.
Wang J F.Optimization on the flow field and gas-liquid mass transfer for a spray tower of WFGD of industrial boiler by numerical simulation[D].Harbin: Harbin Institute of Technology, 2011.
陈晓利.脱硫塔内雾化蒸发及反应特性数值模拟[D].哈尔滨: 哈尔滨工业大学, 2007.
Chen X L.Numerical simulation of atomization and evaporation and reaction characteristic in the desulfurization tower[D].Harbin: Harbin Institute of Technology, 2007.
赵越.燃煤工业锅炉系统节能评价指标体系的研究与应用[D].南京: 东南大学, 2017.
Zhao Y.Research and application of energy-saving evaluation index system for coal-fired industrial boiler system[D].Nanjing: Southeast University, 2017.
刘剑.燃煤机组湿法脱硫系统能效评估方法研究[J].电气应用, 2013(S2):91-94.
Liu J.Research on energy efficiency evaluation method of wet desulfurization system for coal-fired unit[J]. Electrotechnical Application, 2013(S2):91-94.
史梦洁.石灰石-石膏湿法脱硫系统综合能效评估方法研究[D].北京: 华北电力大学, 2014.
Shi M J.Research on energy efficiency assessment of limestone-gypsum wet desulphurization system[D]. Beijing: North China Electric Power University, 2014.
王彪.石灰石-石膏湿法脱硫系统模糊评价方法研究及应用[D].北京: 华北电力大学, 2013.
Wang B.Fuzzy evaluation method research and applications on limestone-gypsum wet FGD system[D].Beijing: North China Electric Power University, 2013.
Lin Y M, Gao X, Shi P P, et al.Numerical simulation on resistance characteristic of large scale wet flue gas desulphurization spraying scrubber[J].Proceedings of the CSEE, 2008, 28(5):28-33.
Marocco L, Inzoli F.Multiphase Euler-Lagrange CFD simulation applied to wet flue gas desulphurisation technology[J].International Journal of Multiphase Flow, 2009, 35(2):185-194.
Chen Z, You C, Liu H, et al.The synergetic particles collection in three different wet flue gas desulfurization towers:a pilot-scale experimental investigation[J]. Fuel Processing Technology, 2018, 179:344-350.
Qin M C, Dong Y, Cui L, et al.Pilot-scale experiment and simulation optimization of dual-loop wet flue gas desulfurization spray scrubbers[J].Chemical Engineering Research and Design, 2019, 147:280-290.
Xu G, Yuan X, Yang Y P, et al.Optimization operation of flue gas desulfurization systems in power plants for energy conservation[J].Proceedings of the CSEE, 2012, 32(32):22-29.
Yang Y P, Yuan X, Huang S W, et al.Regressive analysis of energy consumption of the wet desulfurization system in thermal power plant[J].Journal of Engineering Thermophysics, 2012, 33(11):1854-1859.