Guohua QIU, Pengzhi XU. Analysis on Corrosion Causes of Induced Draft Fan Blade in Circulating Fluidized Bed Boiler With Mixed Burning Solid Waste Fuel[J]. Power Generation Technology, 2020, 41(6): 681-688.
DOI:
Guohua QIU, Pengzhi XU. Analysis on Corrosion Causes of Induced Draft Fan Blade in Circulating Fluidized Bed Boiler With Mixed Burning Solid Waste Fuel[J]. Power Generation Technology, 2020, 41(6): 681-688. DOI: 10.12096/j.2096-4528.pgt.20055.
Analysis on Corrosion Causes of Induced Draft Fan Blade in Circulating Fluidized Bed Boiler With Mixed Burning Solid Waste Fuel
为研究某掺烧固废燃料的2×300 MW循环流化床机组引风机叶片腐蚀严重的原因,对腐蚀区域叶片和不同位置的灰进行了取样分析。X光衍射光谱(X-Ray diffractomer,XRD)、扫描电镜(scanning electron microscope,SEM)、X射线荧光光谱(X-ray fluorescence,XRF)等分析结果表明:在叶片锈样中和叶片表面均发现有Cl元素,未发现S元素,由此确定叶片腐蚀的原因是Cl腐蚀;通过对锅炉不同位置灰样的化验,发现空预器板结灰和半干法脱硫塔后布袋除尘器捕集的脱硫灰出现了Cl元素富集的情况,这是引起设备Cl腐蚀的
关键。掺烧的固废燃料和污泥是Cl的主要来源,板结灰中的Cl富集与选择性非催化还原逃逸的NH
3
有关,而脱硫灰中Cl富集的原因有待进一步研究确定。
Abstract
In order to study the reasons for serious corrosion problem of induced draft fan blades of a 2×300 MW circulating fluidized bed unit which were blended burning solid waste fuel
the samples of the corroded blade and ash from different positions were taken. The analysis results of X-Ray diffractomer (XRD)
scanning electron microscope (SEM) and X-ray fluorescence (XRF) show that Cl element is found in the rust samples and on the surface of the blades
and no trace of S element is found. Therefore
it is determined that the cause of the corrosion of the blades is Cl corrosion. Through the test of ash samples at different positions of the boiler
it is found that the ash hardened on the air preheater and the ash collected by bag filter behind the semi-dry flue gas desulfurization are enriched in Cl
which is the key to cause the Cl corrosion of the equipment. The blended burning solid waste fuel and sludge are the main sources of Cl. The enrichment of Cl in the ash hardened on the air preheater is found related to NH
3
escaped from selective non-catalytic reduction
the reason of Cl enrichment in desulfurized ash needs further study.
ZHANG J B, HAO W, ZHAO Z J, et al.Theoretical and practical research on mechanism of low-temperature corrosion caused by boiler flue gas[J].Journal of Chinese Society of Power Engineering, 2011, 31(10):730-733.
CHEN Z M, LIU H X, CUI Y, et al.Study on generation, hazard, testing and emission characteristics of SO 3 in flue gas of coal-fired power plants[J ] .Power Generation Technology, 2019, 40(6):564-569.
CHEN J J, TONG J L.Analysis and control of low-temperature corrosion of electric induced draftfan and flue in power plants[J].Zhejiang Electric Power, 2019, 38(2):94-97.
CHEN X, XU W.Vibration treatment of centrifugal induced draft fan by tail gas corrosion in waste incineration power plant[J].Shanxi Electric Power, 2019(5):56-58.
LI X, ZHANG C, LIA Y, et al.The status of municipal solid waste incineration (MSWI) in China and its clean development[J].Energy Procedia, 2016, 104:498-503.
ZHANG S X, CAI F L, CHEN Y H, et al.Feasibility analysis of large CFB boiler mixed burning biomass fuels and urban solid waste[J].China Resources Comprehensive Utilization, 2017, 35(7):64-68.
WANG L J.Optimization and comprehensive utilization technology of waste incineration power generation system[J].Power Generation Technology, 2019, 40(4):377-381.
FANG D Z, LI K X.An overview of power generation from municipal solid waste incineration plants at home and abroad[J].Power Generation Technology, 2019, 40(4):367-376.
LI D X, XU H E, NIU Y J, et al.Experimental study on SO 3 generation and emission of a 300 MW energy saving CFB boiler[J ] .Journal of Chinese Society of Power Engineering, 2020, 40(6):447-453.
ZENG Y J.Experimental study on co-removal of SO 3 and Hg 0 from pellet flue gas by semi-dry flue gas desulfurization[D ] .Beijing: North China Electric Power University, 2019..
KE Y J, CHEN Q Y, ZHANG L N.Study on the technique of utilization of municipal sewage sludge[J].China Resources Comprehensive Utilization, 2008(8):13-16.
LI L M, JIN J R, SUN J, et al.Ash accumulation analysis of air preheater in biomass circulating fluidized bed boiler[J].Equipment Management and Maintenance, 2017, 50(4):99-101.
DONG R F, WU W L, WANG F T, et al.Reason analysis and countermeasures of ammonium chloride crystallization in the flue system of coal-fired power plants after ultra-low emission transformation[J].Thermal Power Generation, 2018, 47(3):128-134.
LIU J Y, HUANG L M, CHEN J C, et al.Effects of the interactions of Cl, sulfur, phosphorus and minerals during sewage sludge co-incineration on the migration and transformation of Cd[J].Acta Scientiae Circumstantiae, 2016, 36(12):4407-4420.
WANG Q M, ZHANG X H, YANG H R, et al.Mechanism ofbiomass ash fouling and pit corrosion in the low temperature surface[J].Industrial Boiler, 2011(2):1-4.
ZHAOZ Z, WANG Y, LIU B, et al.Experimental study on corrosion characteristics of ternary mixed chloride salt NaCl-KCl-MgCl 2 [J ] .Power Generation Technology, 2018, 39(6):561-565.
ZHU J Z, CHEN L Q, GAN G.Corrosion mechanism of alkali chloride during the incineration of refuse[J].Journal of South China University of Technology (Natural Science), 2005, 33(3):78-82.
Analysis of Influence of Flue Gas Recirculation on Thermodynamic Performance and Economic Efficiency of 125 MW Supercritical CO2 Coal-Fired Power Generation Unit
Optimization Method of Flow Field for Alleviating Clogging of Mist Eliminator in Desulfurization Tower
Application Status and Existing Problem Analysis of the Natural Draft Cooling Towers With Flue Gas Injection Technology in Thermal Power Plants
Experimental Study on the Air Gasification Characteristics of Agricultural and Forestry Waste in a Circulating Fluidized Bed
Research and Application of Deep Peak Shaving of 350 MW Supercritical Fluidized Bed Unit
Related Author
XIANG Jun
CHEN Jing
LIU Hui
ZHU Meng
WANG Can
CHEN Lei
ZHOU Jing
HU Song
Related Institution
State Key Laboratory of Coal Combustion (Huazhong University of Science and Technology)
CHN Energy Group New Energy Technology Research Institute Co., Ltd., Chaoyang District
GD Power Development Co., Ltd., Chaoyang District
School of Energy and Power Engineering, Changsha University of Science and Technology
Department of Environmental Science and Engineering, North China Electric Power University