Cause Analysis and Control Countermeasures of Slurry Overflow in Desulfurization Absorber Tower Wastewater Pit
In the #1 absorption tower of a power plant wet flue gas desulfurization (WFGD) system
a large number of slurry overflowed from effluent pit
the gypsum moisture content beyond index and mist eliminator was blocked. Through analysis
the main reasons were the high load of absorption tower
the fast flow rate of the tower
the insufficient oxidation of calcium sulfite
the high slurry density in the absorption tower and the less desulfurization absorption slurry atomization particles. Combined with the ultra-low renovation project of the desulfurization system
some equipment expansion was implemented such as increasing the spray layer and backup swirl
switching to the one-way double-headed nozzle and three-roof ridge efficient demisters
installing the stainless-steel tray and synergistic ring on tower wall. Meanwhile
some improvement measures were put forward
such as controlling the pH value and density of the absorption tower
adding desulfurization synergist
increasing the number of oxidation fan operation and improving the demister cleaning frequency.