Junhua CHEN, Wenjie ZHANG, Pengzhi XU, et al. Experimental and Analysis on Optimization of a Boiler in Power Plant[J]. Power Generation Technology, 2019, 40(1): 61-65.
DOI:
Junhua CHEN, Wenjie ZHANG, Pengzhi XU, et al. Experimental and Analysis on Optimization of a Boiler in Power Plant[J]. Power Generation Technology, 2019, 40(1): 61-65. DOI: 10.12096/j.2096-4528.pgt.18153.
Experimental and Analysis on Optimization of a Boiler in Power Plant
In order to improve boiler efficiency and reduce the emission of boiler pollutants
this paper take a power plant as the research object
the overall optimization of the boiler's air preheater seal device horizontal flue ash blower system and high-pressure economizer.were carried out
chemical cleaning and heat treatment were also carried out for bolier
and the thermal efficiency and pollutant discharge of the boiler ware tested before and after the optimization. Compared with that before the optimization
the efficiency of boiler is increased by 2.3% under different loads and the coal consumption is reduced at the same time. The unburned carbon heat loss and the air leakage rate of air preheater is also greatly reduced. The concentration of NO
x
discharged from the boiler has reached the requirement. The optimized reform has achieved the expected effect.