An Energy Consumption Analysis of Air-conditioning System with Divided Function Fresh Air-Supplementary Air at Laboratories in Hot and Humid Areas
Laboratories with air-conditioning system in hot and humid areas consume much more air-conditioning energy than conventional public buildings. One of the most important reasons is that energy consumption from air-conditioning fresh air
caused by exhaust air
accounts for a large proportion of air-conditioning energy consumption in the laboratories in hot and humid areas. An independent fresh air-supplementary air system is proposed to minimize the fresh air volume and load from fresh air in the laboratories
and the energy saving effect of this system is analyzed in combination with a practical case. The results show that the energy saving rate of the “multi-split air conditioner + divided function fresh air-supplementary air” air-conditioning system based on the divided function design is up to 65.6%
compared with the conventional “multi-split air conditioner + fresh air” air-conditioning system.
关键词
Keywords
references
JOHNSON, GREGORY R. HVAC design for sustainable lab [J]. ASHRAE Journal, 2008, 9(50): 24-34.
REN S B, YU W J. Case Analysis on chemical lab oratory ventilation energy saving retrofit [J]. Contamination Control and Air-conditioning Technology, 2018(2): 98-101.
YU C Z, NI X S, WANG Z G. VAV systems in laboratory ventilation control application [J]. Contamination Control and Air-conditioning Technology, 2014(4): 64-65.
NA L L, DANIEL H. Energy efficient HVAC systems for labs [J]. ASHRAE Journal, 2014, 4(56): 58-64.
ZHAO M H, SHEN J M. Applications and controls of VAV in laboratory ventilation and air conditioning [J]. Contamination Control and Air-conditioning Technology, 2004(1): 45-49.
LAI W B. Ventilation and air conditioning system design of the chemical laboratory [J]. Refrigeration, 2007, 2(26): 73-76.
ZHANG W J. Air conditioning and ventilation system design of a laboratory [J]. HVAC, 2013, 5(43): 43-45.
ZUO X. Discussion on energy efficiency design method for laboratory air conditioning and ventilation project [J]. HVAC, 2013, 5(43): 22-27.
ZHOU Z Y. Views on ventilation and air conditioning engineering design in modern laboratory [J]. HVAC, 2013, 5(43): 1-9.
LI J. YIN K C, SONG X C, et al . Design of ventilation and air-conditioning system for lab building of a university in Beijing [J ] . HVAC, 2015, 45(9): 38-41.
张链. 基于热回收技术的独立新风系统的节能研究[D]. 天津: 天津大学, 2017.
MADINEEDI N T, HARRELL J M, MATHIAS J A. Redesigning the HVAC system of a university laboratory building[M]. ASHRAE Transactions, 2017, 123(2): 217-228.
WANG H S, PAN Z C. Design of VAV system in drug R D laboratory [J]. Contamination Control and Air-conditioning Technology, 2018(1): 87-90.
LYU Q M, WANG C H, HUANG P J. Analysis of the application of energy saving technology to air conditioning systems on the subtropical campus [J]. Journal of Guangdong University of Technology, 2012, 29(2): 63-67.