WANG Weiliang, LYU Junfu, YAO Hong, et al. Reconstruction and development of thermodynamic systems for flexible coal-fired power[J]. 2026, 59(9): 83-95.
WANG Weiliang, LYU Junfu, YAO Hong, et al. Reconstruction and development of thermodynamic systems for flexible coal-fired power[J]. 2026, 59(9): 83-95.DOI: 10.11930/j.issn.1004-9649.202607046.
Reconstruction and development of thermodynamic systems for flexible coal-fired power
Against the backdrop of the "dual-carbon" goals and the new power systems
coal-fired power generation is accelerating its transition toward deep and flexible peak-shaving. However
when coal-fired units operate at low-load conditions
prominent challenges including substantial degradation in safety and reliability as well as sharp growth in coal consumption remain to be addressed. To this end
this study systematically elaborates the theoretical methodology of thermodynamic system reconstruction
analyzes its influences on boiler combustion stability
hydrodynamic characteristics
heating-surface metal safety
and emission control under low-load conditions
and discusses its improvement effects on heat consumption at low loads. By establishing a correlation mechanism of "key performance-characteristic parameters-key-component structures"
the proposed theoretical methodology employs modular thermodynamic system topology control and flow-field reconstruction to raise characteristic parameters such as feed-water temperature
main-steam pressure
and steam flow-field under low-load operating conditions to levels close to their rated values. Research on a 1000 MW ultra-supercritical unit shows that
at 30%~50% rated load range
this technology can increase feed-water temperature
the flue gas temperature for selective catalytic reduction (SCR) denitrification and hot air temperature by approximately 65 ℃
44 ℃ and 30 ℃
respectively
significantly improving key performance indicators including low-load combustion stability
hydrodynamic and heating-surface safety
and SCR reliability. Meanwhile
it reduces the net coal consumption for power supply by 8~27 g/(kW·h)
offsetting about 55% of the coal-consumption increment of conventional units at low-load operation. Conducting research on turbine ultra-low load operation technology based on this theory represents an important development direction for flexible coal-fired power thermodynamic systems.