Botong Li, Dingchuan Zheng, Bin Li, et al. Analysis of low voltage ride-through capability and optimal control strategy of doubly-fed wind farms under symmetrical fault[J]. Protection and Control of Modern Power Systems, 2023, 8(2): 1-15.
DOI:
Botong Li, Dingchuan Zheng, Bin Li, et al. Analysis of low voltage ride-through capability and optimal control strategy of doubly-fed wind farms under symmetrical fault[J]. Protection and Control of Modern Power Systems, 2023, 8(2): 1-15.DOI: 10.1186/s41601-023-00310-0.
Analysis of low voltage ride-through capability and optimal control strategy of doubly-fed wind farms under symmetrical fault
Given the “carbon neutralization and carbon peak” policy
enhancing the low voltage ride-through (LVRT) capability of wind farms has become a current demand to ensure the safe and stable operation of power systems in the context of a possible severe threat of large-scale disconnection caused by wind farms. Currently
research on the LVRT of wind farms mainly focuses on suppressing rotor current and providing reactive current support
while the impact of active current output on LVRT performance has not been thoroughly discussed. This paper studies and reveals the relationship between the limit of reactive current output and the depth of voltage drop during LVRT for doubly-fed induction generator (DFIG) based wind farms. Specifically
the reactive current output limit of the grid-side converter is independent of the depth of voltage drop
and its limit is the maximum current allowed by the converter
while the reactive current output limit of the DFIG stator is a linear function of the depth of voltage drop. An optimized scheme for allocating reactive current among the STATCOM
DFIG stator
and grid-side converter is proposed. The scheme maximizes the output of active current while satisfying the standard requirements for reactive current output. Compared to traditional schemes
the proposed LVRT optimization strategy can output more active power during the LVRT period
effectively suppressing the rate of rotor speed increase
and improving the LVRT performance and fault recovery capability of wind farms. Simulation results verify the effectiveness of the proposed scheme.
Abstract
Given the “carbon neutralization and carbon peak” policy
enhancing the low voltage ride-through (LVRT) capability of wind farms has become a current demand to ensure the safe and stable operation of power systems in the context of a possible severe threat of large-scale disconnection caused by wind farms. Currently
research on the LVRT of wind farms mainly focuses on suppressing rotor current and providing reactive current support
while the impact of active current output on LVRT performance has not been thoroughly discussed. This paper studies and reveals the relationship between the limit of reactive current output and the depth of voltage drop during LVRT for doubly-fed induction generator (DFIG) based wind farms. Specifcally
the reactive current output limit of the grid-side converter is independent of the depth of voltage drop
and its limit is the maximum current allowed by the converter
while the reactive current output limit of the DFIG stator is a linear function of the depth of voltage drop. An optimized scheme for allocating reactive current among the STATCOM
DFIG stator
and grid-side converter is proposed. The scheme maximizes the output of active current while satisfying the standard requirements for reactive current output. Compared to traditional schemes
the proposed LVRT optimization strategy can output more active power during the LVRT period
efectively suppressing the rate of rotor speed increase
and improving the LVRT performance and fault recovery capability of wind farms. Simulation results verify the efectiveness of the proposed scheme.
Transient Stability Analysis and Coordinated Control Strategy of DC-Link Voltage for PLL-Based Grid-Connected DFIG System During Asymmetrical Grid Faults
Dynamic Coupling and Cooperative Control for Multi-Paralleled Doubly Fed Induction Generator Wind Farms During Symmetrical Low Voltage Ride-Through in a Weak Grid
Coordinated control by ADRC strategy for a wind farm based on SCIG considering low voltage ride-through capability
Improving low-voltage ride-throughcapability of a multimegawatt DFIG basedwind turbine under grid faults
A direct power control of a DFIG based-WECS during symmetrical voltage dips
Related Author
Yi Luo
Jun Yao
Dong Yang
Hai Xie
Linsheng Zhao
Rongyu Jin
Lei Guan
Hammadi Laghridat
Related Institution
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University
Higher National School of Arts and Crafts (ENSAM), Mohammed V University
National High School for Computer Science and Systems Analysis (ENSIAS), Mohammed V University
Research Center of Engineering and Health Science and Technologies (STIS), High Normal School of Technical Education (ENSET), Mohammed V University
Research Center of Engineering and Health Science and Technologies, Higher National School of Computer Science and Systems Analysis (ENSIAS), Mohammed V University