Tummala S. L. V. Ayyarao. Modified vector controlled DFIG windenergy system based on barrier functionadaptive sliding mode control[J]. Protection and Control of Modern Power Systems, 2019, 4(1).
DOI:
Tummala S. L. V. Ayyarao. Modified vector controlled DFIG windenergy system based on barrier functionadaptive sliding mode control[J]. Protection and Control of Modern Power Systems, 2019, 4(1).DOI: 10.1186/s41601-019-0119-3.
Modified vector controlled DFIG windenergy system based on barrier functionadaptive sliding mode control
Increased penetration of wind energy systems has serious concerns on power system stability. In spite of several advantages
doubly fed induction generator (DFIG) based wind energy systems are very sensitive to grid disturbances. DFIG system with conventional vector control is not robust to disturbances as it is based on PI controllers. The objective of this paper is to design a new vector control that is robust to external disturbances. To achieve this
inner current loop of the conventional vector control is replaced with sliding mode control. In order to avoid chattering effect and achieve finite time convergence
the control gains are selected based on positive semi-definite barrier function. The proposed barrier function adaptive sliding mode (BFASMC) is evaluated by testing it on a benchmark multi-machine power system model under various operating conditions. The simulated results show that the proposed method is robust to various disturbances.
Abstract
Increased penetration of wind energy systems has serious concerns on power system stability. In spite of several advantages
doubly fed induction generator (DFIG) based wind energy systems are very sensitive to grid disturbances. DFIG system with conventional vector control is not robust to disturbances as it is based on PI controllers. The objective of this paper is to design a new vector control that is robust to external disturbances. To achieve this
inner current loop of the conventional vector control is replaced with sliding mode control. In order to avoid chattering effect and achieve finite time convergence
the control gains are selected based on positive semi-definite barrier function. The proposed barrier function adaptive sliding mode (BFASMC) is evaluated by testing it on a benchmark multi-machine power system model under various operating conditions. The simulated results show that the proposed method is robust to various disturbances.
Impact of Control Interaction of Wind Farm with MMC-HVDC Transmission System on Distance Protection Adaptability under Symmetric Fault
Dynamic Coupling and Cooperative Control for Multi-Paralleled Doubly Fed Induction Generator Wind Farms During Symmetrical Low Voltage Ride-Through in a Weak Grid
Review of sub-synchronous interaction in wind integrated power systems: classification, challenges, and mitigation techniques
A robust composite wide area control of aDFIG wind energy system for dampinginter-area oscillations
Asymmetric GARCH type models forasymmetric volatility characteristics analysisand wind power forecasting
Related Author
Linsheng Zhao
Rongyu Jin
Yongchao Lin
Jun Yao
Tian Zhang
Lei Guan
Narendra Kumar
Fausto Pedro García Márquez
Related Institution
State Grid Jiangsu Electric Power Co., Ltd, Maintenance Branch Company