Swagata Das, Sundaravaradan Navalpakkam Ananthan, Surya Santoso. Relay performance verification using faultevent records[J]. Protection and Control of Modern Power Systems, 2018, 3(3): 1-10.
DOI:
Swagata Das, Sundaravaradan Navalpakkam Ananthan, Surya Santoso. Relay performance verification using faultevent records[J]. Protection and Control of Modern Power Systems, 2018, 3(3): 1-10.DOI: 10.1186/s41601-018-0094-0.
Relay performance verification using faultevent records
Introduction: Event reports recorded by intelligent electronic devices (IEDs) such as digital relays and fault recorders during disturbances depict the status and system parameters of the power system. Incorrect relay settings and unknown system parameters can lead to relay misoperation but information regarding these are available by performing a comprehensive analysis of fault records. Hence
it is necessary to regularly make a comprehensive assessment of the functioning of the relay to ensure reliable operation. Case description: The objective of this paper is to demonstrate various aspects of evaluating relay performance and verifying circuit parameters which are used in relay settings using field data in two case studies. Discussion and Evaluation: While scrutinizing the relay's operation
this paper also presents key insights on verifying circuit parameters using the same relay event records. Conclusions: The lessons learned from the case studies presented in this paper will equip a protection engineer to inspect the operation of a relay during a transmission line fault
help gain a better understanding of the fault event and take possible actions to prevent future occurrence of similar events.
Abstract
Introduction: Event reports recorded by intelligent electronic devices (IEDs) such as digital relays and fault recorders during disturbances depict the status and system parameters of the power system. Incorrect relay settings and unknown system parameters can lead to relay misoperation but information regarding these are available by performing a comprehensive analysis of fault records. Hence
it is necessary to regularly make a comprehensive assessment of the functioning of the relay to ensure reliable operation. Case description: The objective of this paper is to demonstrate various aspects of evaluating relay performance and verifying circuit parameters which are used in relay settings using field data in two case studies. Discussion and Evaluation: While scrutinizing the relay’s operation
this paper also presents key insights on verifying circuit parameters using the same relay event records. Conclusions: The lessons learned from the case studies presented in this paper will equip a protection engineer to inspect the operation of a relay during a transmission line fault
help gain a better understanding of the fault event and take possible actions to prevent future occurrence of similar events.
A review of single phase adaptive autoreclosingschemes for EHV transmissionlines
Impedance Characteristic Analysis and Sensitive Identification Method for Inter-Turn Short Circuits of Ultra-High Voltage Shunt Reactors
Unified Directional Element for Transmission Networks Considering Various Controllers of Inverter-Based Resources
A Pilot Protection Method for Active Distribution Networks Based on Improved Fréchet Distance
Fault location of untransposed double-circuit transmission lines based on an improved Karrenbauer matrix and the QPSO algorithm
Related Author
Waqar Ahmad Khan
Tianshu Bi
Ke Jia
Botong Li
Baoshi Zhang
Wei Dai
Guodong Li
Yincheng Wang
Related Institution
Faculty of Engineering, Lahore Leads University, Lahore, Punjab
State Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, People's Republic of China
State Key Laboratory of Technology and Equipment for Defense against Power System Operational Risks, NARI Group Corporation (State Grid Electric Power Research Institute)
State Key Laboratory of Smart Power Distribution Equipment and System, Key Laboratory of Smart Grid of Ministry of Education, School of Electrical and Information Engineering, Tianjin University
Department of Electrical and Computer Engineering, University of Windsor