Study on effectiveness of L-shaped sediment diversion sills at intake of diversion-type hydropower station
To address severe bed load sedimentation at the intake of a diversion-type hydropower station
this study works out a new L-shaped structure of sediment diversion sills. A laboratory scale model experiment and numerical simulations are used to study the behaviors of these sills on a movable-bed in a case study of a large diversion-type hydropower station. Their hydraulic characteristics and sediment exclusion effectiveness are examined using comparative analysis against the traditional sills of straight shapes
focusing on the effects of their layout parameters (spacing
height
and angle) and hydraulic parameters. Results demonstrate the L-shaped sills achieve superior sediment exclusion performance
effectively diverting sediment away from the intake while minimizing sediment migration behind them. The sill height imposes a critical influence on exclusion efficiency-a 2 m increase leads to a 59% reduction in sediment deposition volume behind the sediment retention sill. The diverting sills maintain effective sediment control under varying diversion ratios and Froude numbers
but as both parameters increase
sediment migrates toward the first upstream sill and deposition increases on its lee side and behind the retention sill. And
the structure causes minimal extra head loss-its average head loss is as low as 0.069 m at the relative sill height of 5 m. Thus
the L-shaped sill and its design provide a novel solution to sediment control in water intake structures.