Farkhodjon Turaev, Isroil Yuldoshev, Khimmatali Juraev, Bozorbek Botirov, Sadullo Fazliddinov, Shakhnoza Rustamova, Local overheating of a photovoltaic module junction box: analysis and recommendations, Clean Energy, Volume 10, Issue 1, February 2026, Pages 29–35, https://doi.org/10.1093/ce/zkaf058DOI:
Local overheating of a photovoltaic module junction box: analysis and recommendations
摘要
Abstract
Local overheating of the junction box on photovoltaic modules is a major barrier to achieving uniform cooling of the entire panel. Even when effective cooling methods are applied
this area often remains a hotspot
limiting the overall cooling performance. We performed outdoor tests on two identical 290-W modules: one without cooling and one with evaporative cooling applied to the backside using ten stitched layers of gauze. Temperatures were monitored by sensors and infrared cameras
including at the junction box. To eliminate the hotspot
the junction box was relocated from the module backsheet to the frame
enabling full-surface cooling coverage. Evaporative cooling reduced the average panel temperature by about 10°C. However
the junction box area remained overheated (50°C–55°C)
similar to the uncooled module. After relocating the junction box to the frame
the hotspot disappeared and the backside temperature became uniform (33°C–35°C). Cooling the panel alone does not ensure uniform temperature distribution due to junction box overheating. Relocating the junction box to the frame is an effective design measure that enables complete cooling coverage and uniform temperature reduction across the entire photovoltaic module.