This study aims to reveal the hydrogen leakage and diffusion characteristics of the hydrogen supply pipeline in a fuel cell patrol vehicle and to evaluate the damage distance following an explosion. Through numerical analysis
the impact of the position
diameter
shape
and direction of leakage holes
as well as ambient wind
on hydrogen diffusion was discussed. The results show that different leakage positions are affected by surrounding objects and the height above the ground
altering the volume and diffusion distance of the flammable hydrogen cloud (FHC). An increase in leakage aperture leads to a significant rise in hydrogen leakage
the volume of the FHC
and the damage range after an explosion. The shape of the leakage hole affects the velocity distribution of hydrogen upon impacting a wall
resulting in a different distribution of the FHC. When the leakage direction is 180°
the volume of the FHC decreases by 79.2%. Environmental winds significantly influence hydrogen diffusion
with lateral winds reducing the volume of the FHC by 74%. The maximum hazard radius of hydrogen leakage is 4.09 m
the maximum distance for multiple fatalities caused by a hydrogen explosion is 1.48 m
and the maximum distance for minor injuries is 6.04 m.