Yuan Yuan, Ruijin Liao. Influence of different anodised nanoporous structures on the anti-icing and electrical properties of transmission Al lines[J]. High Voltage, 2025, 10(1).
DOI:
Yuan Yuan, Ruijin Liao. Influence of different anodised nanoporous structures on the anti-icing and electrical properties of transmission Al lines[J]. High Voltage, 2025, 10(1). DOI: 10.1049/hve2.12471.
Influence of different anodised nanoporous structures on the anti-icing and electrical properties of transmission Al lines
摘要
Ice accumulation of overhead transmission lines can lead to serious damage to power systems. Superhydrophobic nanostructured Al conductors are proposed to replace the de-icing or ice-melting equipment for economic advantages
good anti-icing properties and robust electrical performance. Anodisation under different direct current densities is adopted to fabricate two nanostructures on Al conductors
including the reticular and honeycomb-like nanoporous structures. Compared to pure Al conductors
the anodised surface of honeycomb-like nanoporous structures exhibits lower ice adhesion (3.82 kPa) and ice accumulation. Aluminium conductor steel reinforced treated in the proposed method has also been validated to exhibit a significant anti-glaze icing property. Additionally
corona performance and line loss are experimentally measured and calculated to prove good electrical performance. The 0.27 A Al strand shows the highest corona inception voltage (27.86 kV) and the lowest AC resistance (4.65 Ω/km)
which is attributed to the good dielectric property and heat dissipation. Therefore
the proposed anti-icing transmission conductors show profound application potential for power systems.
Abstract
Ice accumulation of overhead transmission lines can lead to serious damage to power systems. Superhydrophobic nanostructured Al conductors are proposed to replace the de-icing or ice-melting equipment for economic advantages
good anti-icing properties and robust electrical performance. Anodisation under different direct current densities is adopted to fabricate two nanostructures on Al conductors
including the reticular and honeycomb-like nanoporous structures. Compared to pure Al conductors
the anodised surface of honeycomb-like nanoporous structures exhibits lower ice adhesion (3.82 kPa) and ice accumulation. Aluminium conductor steel reinforced treated in the proposed method has also been validated to exhibit a significant anti-glaze icing property. Additionally
corona performance and line loss are experimentally measured and calculated to prove good electrical performance. The 0.27 A Al strand shows the highest corona inception voltage (27.86 kV) and the lowest AC resistance (4.65 Ω/km)
which is attributed to the good dielectric property and heat dissipation. Therefore
the proposed anti-icing transmission conductors show profound application potential for power systems.