Zhichuan Bao, Fang She, Xinyuan Peng, et al. Benzotriazole@ZIF-8 Enhances the Corrosion Resistance and Conductivity of Carbon Nanotube/Epoxy Composite Coatings for Grounding Grid[J]. Electrical Materials and Applications, 2026, 3(1).
DOI:
Zhichuan Bao, Fang She, Xinyuan Peng, et al. Benzotriazole@ZIF-8 Enhances the Corrosion Resistance and Conductivity of Carbon Nanotube/Epoxy Composite Coatings for Grounding Grid[J]. Electrical Materials and Applications, 2026, 3(1).DOI: 10.1049/ema3.70038.
Benzotriazole@ZIF-8 Enhances the Corrosion Resistance and Conductivity of Carbon Nanotube/Epoxy Composite Coatings for Grounding Grid
摘要
A ZB/CNTs/E606 conductive anti-corrosion composite coating was prepared on Q235 steel via a physical blending process. The coating consists of E606 epoxy resin as the matrix
carbon nanotubes (CNTs) as the conductive filler
and a metal-organic framework ZIF-8 encapsulating the corrosion inhibitor benzotriazole (BTA) as a functional modifier (denoted as ZB). The coating with 0.5 wt.% ZB retains low resistivity (∼10−2 Ω·m) after 30-day saline immersion/salt-spray exposure
exhibits high low-frequency (|Z|0.01Hz) impedance (3.3 × 105 Ω·cm2)
and shows no corrosion after 40-day salt-spray testing. Adhesion remains above 10 MPa in all tested conditions. The coating combines sustained conductivity
strong adhesion and active corrosion inhibition
offering a durable solution for grounding systems in aggressive environments.
Abstract
A ZB/CNTs/E606 conductive anti-corrosion composite coating was prepared on Q235 steel via a physical blending process. The coating consists of E606 epoxy resin as the matrix
carbon nanotubes (CNTs) as the conductive filler
and a metal-organic framework ZIF-8 encapsulating the corrosion inhibitor benzotriazole (BTA) as a functional modifier (denoted as ZB). The coating with 0.5 wt.% ZB retains low resistivity (∼10−2 Ω·m) after 30-day saline immersion/salt-spray exposure
exhibits high low-frequency (|Z|0.01Hz) impedance (3.3 × 105 Ω·cm2)
and shows no corrosion after 40-day salt-spray testing. Adhesion remains above 10 MPa in all tested conditions. The coating combines sustained conductivity
strong adhesion and active corrosion inhibition
offering a durable solution for grounding systems in aggressive environments.
Characterisation of Polytetrafluoroethylene Nozzle Failure in Ultra-High Voltage Circuit Breakers
The Temperature Reduction Characteristics of Water Droplets Freezing on Hydrophobic Surface
Multi-Factor Influence Mechanism of Mechanical Stress Distribution During the Service Life of Large Commercial Soft-Pack Batteries
Low-Temperature Co-Firing and Synergistic Performance Optimisation of Ba(Zr0.2Ti0.8)O3 Ceramics Achieved by Doping With Trace Amounts of BaO–B2O3–SiO2 Glass
Breakdown Characteristics of PEEK Insulation Immersed in Synthetic Ester Liquid for Subsea Cable Connectors