Yanhui Xu, Guanlin Li, Yuyuan Gui, et al. Generation of input spectrum for electrolysis stack degradation test applied to wind power PEM hydrogen production[J]. Global Energy Interconnection, 2024, 7(4): 462-474.
DOI:
Yanhui Xu, Guanlin Li, Yuyuan Gui, et al. Generation of input spectrum for electrolysis stack degradation test applied to wind power PEM hydrogen production[J]. Global Energy Interconnection, 2024, 7(4): 462-474.DOI: 10.1016/j.gloei.2024.08.006.
Generation of input spectrum for electrolysis stack degradation test applied to wind power PEM hydrogen production
Hydrogen production by proton exchange membrane electrolysis has good fluctuation adaptability
making it suitable for hydrogen production by electrolysis in fluctuating power sources such as wind power. However
current research on the durability of proton exchange membrane electrolyzers is insufficient. Studying the typical operating conditions of wind power electrolysis for hydrogen production can provide boundary conditions for performance and degradation tests of electrolysis stacks. In this study
the operating condition spectrum of an electrolysis stack degradation test cycle was proposed. Based on the rate of change of the wind farm output power and the time-averaged peak-valley difference
a fluctuation output power sample set was formed. The characteristic quantities that played an important role in the degradation of the electrolysis stack were selected. Dimensionality reduction of the operating data was performed using principal component analysis. Clustering analysis of the data segments was completed using an improved Gaussian mixture clustering algorithm. Taking the annual output power data of wind farms in Northwest China with a sampling rate of 1 min as an example
the cyclic operating condition spectrum of the proton-exchange membrane electrolysis stack degradation test was constructed. After preliminary simulation analysis
the typical operating condition proposed in this paper effectively reflects the impact of the original curve on the performance degradation of the electrolysis stack. This study provides a method for evaluating the degradation characteristics and system efficiency of an electrolysis stack due to fluctuations in renewable energy.
Enhanced physics-inspired algorithm for optimal power flow with renewable energy integration using Coulomb’s and Franklin’s law under climate considerations
Load-forecasting method for IES based on LSTM and dynamic similar days with multi-features
Momentum vectorized adaptive DDPG-based PSC mitigator design for hybrid PV-TEG systems with auxiliary battery participation
Distribution network data asset protection considering multiple topology and multi-dimensional knowledge graph
Negative electricity prices in electricity markets: causes, impacts,and response strategies
Related Author
Afshin Canani
Mohammadamin Mobtahej
Saeid Jowkar
Amin Besharatiyan
Ali Esmaeel Nezhad
Ehsan Rahimi
Fariba Esmaeilnezhad
Toktam Tavakkoli Sabour
Related Institution
Department of Electrical, Electronic, and Information Engineering, University of Bologna, Viale Del Risorgimento 2
Department of Electrical Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran, University Sq, Najafabad, Isfahan
Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, 1012 Boston Ave, Lubbock
Young Researchers and Elite Club, Shiraz Branch, Islamic Azad University Shiraz, 5th Km of Sadra Highway, Shiraz
Department of Electrical Engineering, Lamar University, Beaumont