Aryani, Purwana, Herdiansyah, et al. Advancing indoor environmental quality (IEQ) in Indonesian hospital wards: An integrated importance performance analysis (IPA) and objective approach[J]. Energy and Built Environment, 2026, 7(5): 1217-1229.
DOI:
Aryani, Purwana, Herdiansyah, et al. Advancing indoor environmental quality (IEQ) in Indonesian hospital wards: An integrated importance performance analysis (IPA) and objective approach[J]. Energy and Built Environment, 2026, 7(5): 1217-1229.DOI: 10.1016/j.enbenv.2025.07.004.
Advancing indoor environmental quality (IEQ) in Indonesian hospital wards: An integrated importance performance analysis (IPA) and objective approach
Indoor Environmental Quality (IEQ) plays a critical role in user comfort and health
yet research in Indonesian hospitals has predominantly emphasized objective measurements
often neglecting users’ subjective perceptions. In contrast
global studies assessing IEQ performance using the Importance Performance Analysis (IPA) based on subjective user evaluations. This study addressed this gap by integrating traditional and alternative IPA methods with objective field measurements to assess 17 IEQ elements
covering thermal comfort
indoor air quality
visual comfort
acoustic comfort
and interior quality
in hospital wards. The research was conducted across three hospitals in Jakarta
Indonesia
aiming to identify and prioritize key areas for improvement. A mixed-methods research approach was employed
involving 178 participants (staff
patients
and visitors) in hospital wards. Gap analysis of users’ perception revealed significant performance gaps were identified in 13 out of 17 IEQ attributes. Traditional IPA identified temperature
noise level
natural light
and lighting control as high-priority concerns
alternative IPA expanded this list to 10 IEQ attributes. Both IPA matrices consistently indicated that natural elements
outside view
glare
and thermal control were low-priority. Conversely
space layout
speech privacy
and lighting intensity were found to exceed expectations. Objective measurements confirmed environmental deficiencies: indoor temperatures ranged from 23.4–27.6 °C (above the 22–23 °C Indonesia’s standard)
average CO₂ concentration reached 827 ppm (exceeding the 1 ppm national threshold)
and PM₂.₅ levels averaged 93 μg/m3 (above the 25 μg/m3 limit). Ventilation was inadequate
several rooms failed to meet requirements for natural light access and occupancy density. Integrating objective data with alternative IPA enhances the precision of IEQ improvement prioritization. The combined approach identified nine critical IEQ aspects for improvement: temperature
noise level
natural lighting
air quality
cleanliness
lighting control
room size
air exchange
and air velocity
while humidity was generally satisfactory. Despite varying user roles
findings suggest a shared need for improved indoor comfort. This integrated method offers a more targeted and comprehensive framework for prioritizing IEQ enhancements in hospitals and other building types. This study advances healthcare facility design by combining subjective user perceptions with objective environmental data
offering a robust framework for IEQ assessment and improvement.
Exploring digital twin interfaces for occupant-building interaction to enhance personal comfort and energy efficiency
A multi-method approach to evaluating indoor environmental quality and energy performance in residential college buildings in a humid subtropical region
A multicriteria method to identify and rank IEQ criticalities: Measurements and applications for existing school buildings
Evaluation of airborne transmission risk in university towns based on IEQ surveys
Indoor environmental quality (IEQ) assessment of Nigerian university libraries: A pilot study
Related Author
Ghahramani
Aucremanne
Shah
Lee
Cinzia Buratti
Elisa Belloni
Giacomo Salvadori
Michele Rocca
Related Institution
Department of Energy, Systems, Territory and Constructions Engineering (DESTeC), University of Pisa
Engineering Department, University of Perugia
Department of Building Environment and Energy, College of Civil Engineering, Hunan University
National Center for International Research Collaboration in Building Safety and Environment, Hunan University
Department of Building, School of Environmental Technology, Federal University of Technology, Minna, P.M.B 65, Minna, Niger State