A multi-method approach to evaluating indoor environmental quality and energy performance in residential college buildings in a humid subtropical region
|更新时间:2026-10-08
|
A multi-method approach to evaluating indoor environmental quality and energy performance in residential college buildings in a humid subtropical region
Energy and Built EnvironmentVol. 7, Issue 5, Pages: 1301-1321(2026)
A multi-method approach to evaluating indoor environmental quality and energy performance in residential college buildings in a humid subtropical region[J]. Energy and Built Environment, 2026, 7(5): 1301-1321.
DOI:
A multi-method approach to evaluating indoor environmental quality and energy performance in residential college buildings in a humid subtropical region[J]. Energy and Built Environment, 2026, 7(5): 1301-1321.DOI: 10.1016/j.enbenv.2025.05.006.
A multi-method approach to evaluating indoor environmental quality and energy performance in residential college buildings in a humid subtropical region
Operational performance in built environments is mostly assessed through indoor environmental quality (IEQ)
water consumption
and energy consumption data to foster improvement-oriented strategies. This study investigates the IEQ and energy performance of residential college buildings (RCBs)
including a LEED Silver-certified building
at a Louisianan university in the United States. Variations in occupant satisfaction
hygrothermal conditions
air quality
and energy metrics were assessed across seasons. Comparative evaluations of LEED-certified and non-certified RCBs in humid subtropical climates are scarce
highlighting the need for further exploration. The study employs subjective
objective
and integrated IEQ evaluation models
alongside energy performance evaluations using conventional Energy Use Intensity (EUI) and a novel Energy Utility Quality (EUQ) metric developed for climates like Louisiana’s. An extended IEQ model integrating energy performance with subjective and objective components is also introduced. Findings highlight significant underperformance in acoustic conditions and high humidity levels
posing risks to occupant comfort and health. While the LEED-certified building excelled in the various IEQ performance metrics adopted
its highest EUI attainment and intermediate EUQ ranking in relation to other buildings point to operational inefficiencies requiring targeted intervention. This research underscores the value of holistic IEQ and energy performance evaluations in enhancing occupant comfort
operational efficiency
and sustainability in student housing. The introduced metrics serve as an enhanced pre-audit tool
enabling facility managers to evaluate building performance effectively and make informed decisions. Future studies shall apply these metrics beyond RCBs.
Towards energy-efficient data centers: A comprehensive review of passive and active cooling strategies
Towards a hybrid retrofit planning framework: A data-driven tool for energy retrofit in residential buildings
Exploring digital twin interfaces for occupant-building interaction to enhance personal comfort and energy efficiency
Integration opportunities, energy and financial profitability of photovoltaic systems in dry and hot climates
Development of a parabolic trough collector-based solar oven with heat pipe for efficient drying of kitchen spices
Related Author
Zhonghua Gou
Senhong Cai
Ali Bahadori-Jahromi
Atefeh Abbaspour
Hamidreza Seraj
Ghahramani
Aucremanne
Shah
Related Institution
School of Urban Design, Wuhan University
Department of Civil and Environmental Engineering, School of Computing and Engineering, University of West London, London W55RF
Center for Technology in Water and Wastewater, School of Civil and Environmental Engineering, University of Technology Sydney, Sydney 2007, New South Wales
Department of Mechanical Engineering, Faculty of Engineering, Universitas Malikussaleh, Lhokseumawe
Department of Mechanical and Industrial Engineering, Universitas Syiah Kuala, Banda Aceh