Analysis and Treatment of Bearing Vibration Failure of 350 MW Supercritical Steam Turbine Unit
|更新时间:2025-04-27
|
Analysis and Treatment of Bearing Vibration Failure of 350 MW Supercritical Steam Turbine Unit
Vol. 40, Issue 5, Pages: 55-58(2021)
作者机构:
内蒙古京能康巴什热电有限公司
作者简介:
基金信息:
DOI:
CLC:TM62
Published:2021
稿件说明:
移动端阅览
HE Qiang, YAO Hudong, DOU Jiaxin, et al. Analysis and Treatment of Bearing Vibration Failure of 350 MW Supercritical Steam Turbine Unit[J]. 2021, 40(5): 55-58.
DOI:
HE Qiang, YAO Hudong, DOU Jiaxin, et al. Analysis and Treatment of Bearing Vibration Failure of 350 MW Supercritical Steam Turbine Unit[J]. 2021, 40(5): 55-58.DOI:
Analysis and Treatment of Bearing Vibration Failure of 350 MW Supercritical Steam Turbine Unit
In view of the problem of the abnormal vibration of the high and medium pressure rotor No.1 bearing of a 350 MW steam turbine unit under operating conditions
it is analyzed that the shaft vibration at a fixed speed of 3 000 r/min and load is mainly based on the forced vibration of the fundamental frequency.The main reasons are bearing wear and looseness
the existence of steam flow induced vibration and rotor mass imbalance.The methods were proposed including improving bearing stability by adopting high and medium pressure rotor dynamic balance weight and adjusting bearing tightness and clearance
adjusting the valve sequence of high pressure regulating valve and changing the steam inlet method of the unit
that provide reference for similar problem of same type units.