广东粤电集团公司珠海发电厂,广东,珠海,519050
Published:2004
移动端阅览
[1]刘洋.机组500MW负荷时汽泵跳闸后的处理[J].湖南电力,2004(03):48-49+51.
LIU Yang. Treatment of the Generation Unit with 500MW Load Subject to The T-BFP Trip[J]. 2004, (3): 48-49+51.
[1]刘洋.机组500MW负荷时汽泵跳闸后的处理[J].湖南电力,2004(03):48-49+51. DOI:
LIU Yang. Treatment of the Generation Unit with 500MW Load Subject to The T-BFP Trip[J]. 2004, (3): 48-49+51. DOI:
叙述了 70 0 MW机组 1台汽动给水泵与电动给水泵并列运行时汽动给水泵跳闸后的事故处理经过及处理要点
分析了事故原因
并提出对策及实施方案
The process and main points of treatment of the 700MW coal-fired generation unit subject to the T-BEP trip
with one T-BFP and one M-BFP feeding water in parallel
are described in this paper. The cause of the T-BEP trip is investigated. The strategies and scheme are proposed to treat the trip.