ZHUO Gang. Logic Problem Analysis of Overall Furnace Outfire Protection in Shimen Thermal Power Plant[J]. 2004, (6): 10-12.DOI:
Logic Problem Analysis of Overall Furnace Outfire Protection in Shimen Thermal Power Plant
摘要
对石门电厂 2 0 0 3年 7月 4日的一次全炉膛灭火保护动作对全炉膛灭火保护逻辑进行分析
认为原逻辑中存在层运行信号相互屏蔽
而且油层无火判断条件不合适等现象
提出优化全炉膛灭火保护逻辑
将油层无火判断条件由 2 /4无火改为 3/4无火
Abstract
The outfire protection lo gi c
for overall furnace outfire protection in Shimen Thermal Power Plant that act ed on 7/4/2004
is analyzed in this paper. The electric power enterprise standard and the design principle used by CE company are employed in the analysis. It is pointed out that there exist mutual screen between different layers messages an d inappropriateness of the judging criterion for no fire on the oil layer. An op timal scheme is proposed for the overall furnace outfire protection logic
in wh ich the judging criterion for no fire on the oil layer is evaluated to 3/4 no fi re from 2/4 no fire.