湖南省电力公司试验研究院
Published:2008
移动端阅览
[1]段学农,陈文,雷霖,徐湘沪.回转式空预器局部烧损事故分析及预防[J].湖南电力,2008(05):28-30.
DUAN Xue-nong, CHEN Wen, LEI Lin, et al. Analysis and prevention of local burning loss in rotary air preheater[J]. 2008, (5): 28-30.
[1]段学农,陈文,雷霖,徐湘沪.回转式空预器局部烧损事故分析及预防[J].湖南电力,2008(05):28-30. DOI:
DUAN Xue-nong, CHEN Wen, LEI Lin, et al. Analysis and prevention of local burning loss in rotary air preheater[J]. 2008, (5): 28-30. DOI:
对某电厂空气预热器局部烧损原因进行了详细的分析
原因涉及设计、安装、运行等多个方面
提出了防止类似事故发生的技术措施
对其他机组的调试、运行具有借鉴作用。
The cause of local burning loss in one air preheater was thoroughly analyzed.The design
installation
and operation were all responsible for the burning loss.Technical measurements to prevent similar accidents were proposed
offering reference to other debugging and operation.
0
Views
73
下载量
3
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution