Prevention and analysis on stalling of primary axial-flow fan for 1000MW ultra-supercritical power units
Stalling occurred many times during parallel operation for a primary axial-flow fan in given 1000MW unit.Stalling problem was analysed
meanwhile adjustment and prevention measurements were proposed to avoid or reduce stalling in the paper.Air-flue system design feature and fan inherent performance were the main reason.Adding a recirculating-air at the outlet to increase air ventilation quantity can improve the operation security of primary fan.