LIN Kai, Li De-wu. Research on the relationship between bushing defect and closing law of main inlet valve in Huizhou Pumped Storage Power Plant[J]. 2014, 34(6): 10-12.
LIN Kai, Li De-wu. Research on the relationship between bushing defect and closing law of main inlet valve in Huizhou Pumped Storage Power Plant[J]. 2014, 34(6): 10-12.DOI:
Research on the relationship between bushing defect and closing law of main inlet valve in Huizhou Pumped Storage Power Plant
摘要
惠州抽水蓄能电站进水阀原轴套在机组投运后不到一年即出现了故障
现场检查发现轴套自润滑材料脱落卡塞进水阀枢轴
以致进水阀无法正常开启
对各种工况受力分析发现轴套在静态下受力最大
说明原轴套的损坏与进水阀参与过渡过程调节无关。经排查原轴套制造工艺存在缺陷
导致自润滑材料脱落。对轴套进行换型后已运行达一年
进水阀各项运行指标保持稳定
进一步验证了进水阀参与过渡过程调节与原轴套故障无必然联系。
Abstract
The primary bushings of main intake valve in Huizhou Pumped Storage Power Station were found damaged in less than a year after the commercial operation. The site inspections showed that the self-lubricating material of the inlet valve bushing fell off and was jammed into the valve trunnion which caused the inlet valve cannot be opened normally. Through the forces analysis under all the different operation conditions
it was found that the bushing bore the largest force in its static state
which indicated that
main inlet valve involved in the transition regulation was irrelevant to the bushing damage. The manufacturing defects were confirmed to be the main cause of the fallen self-lubricating material. In one year after the replacement of the new type bushings
all the operation conditions of the inlet valve were normal and stable
which further proved that the inlet valve involved in the transition regulation had nothing to do with the damage of primary bushing.