LI Wenjun, LYU Dangzhen, DUAN Xuenong. Thermal calculation and experimental studies on flue gas and steam temperature deviation of supercritical boiler[J]. 2015, 35(4): 14-17.
LI Wenjun, LYU Dangzhen, DUAN Xuenong. Thermal calculation and experimental studies on flue gas and steam temperature deviation of supercritical boiler[J]. 2015, 35(4): 14-17.DOI:
Thermal calculation and experimental studies on flue gas and steam temperature deviation of supercritical boiler
摘要
针对大型电站超临界锅炉烟温与汽温偏差问题
结合国内首台600 MW超临界W型锅炉
重点研究不同负荷下汽水分离器出口汽温偏差
以及尾部受热面汽温偏差变化规律
并从优化汽温偏差出发
首次提出汽水分离器出口管道交叉布置结构
从而改变汽水流动方向
并结合锅炉热力计算
验证交叉布置结构减少汽温偏差的效果:当采用汽水分离器出口交叉布置结构后
屏式过热器入口左、右侧汽温偏差减小到原汽温偏差的1/2左右。
Abstract
To solve the problems of flue gas and steam temperature deviation of supercritical boiler
the temperature deviation of the steam separator and the following heating surface are investigated in the domestic first 600 MW supercritical W-shaped flame boiler. Moreover
a special outlet cross layout structure of steam separator is designed and the role of the special outlet cross structure is investigated by thermal calculation. The results indicate that the steam temperature deviation of supercritical boiler is increased with the the flue gas temperature deviation and the growth of the following heating surface during actual operation.Meanwhile
the special outlet cross layout structure of steam separator has a remarkable effect on decreasing the steam temperature deviation
which has been reduced to half of the original level. Therefore
the special outlet cross layout structure of supercritical boiler steam separator is worthwhile to distinctly decrease the steam temperature deviation and increase the safe in operation of supercritical boil.